Relationship between ocular pulse amplitude and systemic blood pressure measurements
- 17 April 2009
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 87 (3) , 329-334
Abstract
: Purpose: This study aimed to determine whether ocular pulse amplitude (OPA) measured with dynamic contour tonometry (DCT) is related to systemic blood pressure (BP) parameters.Methods: Blood pressure was measured continuously and simultaneously with OPA in one randomly selected eye in 29 healthy subjects. Systemic parameters of interest were: systolic and diastolic BPs and their difference (BP amplitude), and left ventricle ejection time (LVET; defined as the time between the diastolic trough and the incisural notch in the BP curve). In addition, the axial length (AL) of the eye was measured. Associations between OPA, AL and systemic cardiovascular parameters were analysed in a multivariate regression model.Results: Measurements of OPA ranged from 1.0 mmHg to 4.9 mmHg (mean 2.3 ± 0.9 mmHg, median 1.9 mmHg). In a univariate analysis with one predictor at a time, means of intraocular pressure (IOP) (p = 0.008), AL (p = 0.046) and LVET (p = 0.037) were significantly correlated with OPA, whereas systolic and diastolic BPs and their amplitude were not. A multiple linear regression analysis showed that mean IOP (p < 0.005), AL (p = 0.01) and LVET (p = 0.002) all independently contributed to OPA.Conclusions: The OPA readings measured with DCT in healthy subjects were not related to BP levels and amplitude. It seems that the OPA strongly depends on the time−course of the cardiac contraction. Regulating mechanisms in the carotid system as well as scleral rigidity may be responsible for dampening the direct effect of BP variations.Keywords
This publication has 34 references indexed in Scilit:
- 24-h blood pressure monitoring in normal tension glaucoma: night-time blood pressure variabilityJournal of Human Hypertension, 2005
- Dynamic Contour TonometryJournal of Glaucoma, 2005
- Baroreceptors, baroreceptor unloading, and the long-term control of blood pressureAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2005
- Choroidal blood flow and arterial blood pressureEye, 2003
- Pressure-volume relation for the living human eyeCurrent Eye Research, 2000
- Choroidal Myogenic Autoregulation and Intraocular PressureExperimental Eye Research, 1994
- Evaluation of non-invasive blood pressure measurement by the Finapres method at rest and during dynamic exercise in subjects with cardiovascular insufficiencyClinical Autonomic Research, 1994
- Ocular Pulse Amplitude in MyopiaJournal of Ocular Pharmacology and Therapeutics, 1991
- The ocular pulseCurrent Eye Research, 1981
- VOLUMETRIC STUDIES OF OPHTHALMIC ARTERY PERFUSION PRESSURE AND OCULAR RIGIDITYActa Ophthalmologica, 1971