Cyclic Loading of 3 Achilles Tendon Repairs Simulating Early Postoperative Forces
- 9 February 2009
- journal article
- research article
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 37 (4) , 786-790
Abstract
Accelerated rehabilitation has been advocated after Achilles tendon repair, but it produces significant forces at the repair site. Stresses applied to the repaired Achilles tendon simulating postoperative forces may exceed the strength of some repairs. Controlled laboratory study. Fifteen Achilles tendons were incised 4 cm proximal to the calcaneal insertion, then were repaired using either a percutaneous, 4-strand Krackow, or an epitendinous augmented 4-strand Krackow technique. Tendons were cyclically loaded to 1000 cycles each at 100, 190, and 369 N. The number of cycles to initial gapping, 5-mm gapping, and total failure were compared using Mann-Whitney U tests with adjustments for multiple comparisons. Gap resistance was significantly greater for augmented Krackow repairs (2208 cycles to initial gapping) versus nonaugmented repairs (502 cycles, P = .024) and for nonaugmented Krackow repairs versus percutaneous repairs (5 cycles, P = .024). All percutaneous repairs failed during the 100-N cycling (102 ± 135 cycles). All nonaugmented Krackow repairs failed during the 190-N cycles (total cycles to failure: 1268 ± 345). All augmented Krackow repairs were intact (no gapping) after the 190-N cycles. Four failed during 369-N cycling (total cycles to failure, 2017 ± 11), and 1 remained intact for 3000 cycles. Epitendinous cross-stitch weave augmentation of Achilles tendon repairs significantly increased repair strength and gap resistance. Epitendinous cross-stitch weave augmentation of Achilles tendon repairs may better allow for early stretching and ambulation after Achilles tendon repair.Keywords
This publication has 29 references indexed in Scilit:
- Open versus percutaneous repair in the treatment of acute Achilles tendon rupture: a randomized prospective studyKnee Surgery, Sports Traumatology, Arthroscopy, 2007
- Modified percutaneous repair of ruptured Achilles tendonKnee Surgery, Sports Traumatology, Arthroscopy, 2007
- Percutaneous and Minimally Invasive Techniques of Achilles Tendon RepairClinical Orthopaedics and Related Research, 2007
- Anatomy of the sural nerve in a computer-assisted model: implications for surgical minimal-invasive Achilles tendon repairBritish Journal of Sports Medicine, 2007
- Percutaneous versus Open Repair of the Ruptured Achilles TendonThe American Journal of Sports Medicine, 2005
- Percutaneous versus Open Tendo Achillis RepairFoot & Ankle International, 2004
- The relative stress on the Achilles tendon during ambulation in an ankle immobiliser: implications for rehabilitation after Achilles tendon repairBritish Journal of Sports Medicine, 2001
- Early Active Motion and Weightbearing After Cross-Stitch Achilles Tendon RepairThe American Journal of Sports Medicine, 1998
- Achilles tendon loading during walking: application of a novel optic fiber techniqueEuropean Journal of Applied Physiology, 1998
- Augmented Repair of Achilles Tendon RupturesThe American Journal of Sports Medicine, 1997