Fast blood flow monitoring in deep tissues with real-time software correlators
Open Access
- 3 February 2016
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (3) , 776-797
Abstract
We introduce, validate and demonstrate a new software correlator for high-speed measurement of blood flow in deep tissues based on diffuse correlation spectroscopy (DCS). The software correlator scheme employs standard PC-based data acquisition boards to measure temporal intensity autocorrelation functions continuously at 50 – 100 Hz, the fastest blood flow measurements reported with DCS to date. The data streams, obtained in vivo for typical source-detector separations of 2.5 cm, easily resolve pulsatile heart-beat fluctuations in blood flow which were previously considered to be noise. We employ the device to separate tissue blood flow from tissue absorption/scattering dynamics and thereby show that the origin of the pulsatile DCS signal is primarily flow, and we monitor cerebral autoregulation dynamics in healthy volunteers more accurately than with traditional instrumentation as a result of increased data acquisition rates. Finally, we characterize measurement signal-to-noise ratio and identify count rate and averaging parameters needed for optimal performance.Keywords
Funding Information
- American Heart Association (AHA) (14POST20460161)
- Application Foundation and Ad- vanced Technology Research Program of Tianjin (14CZDJC33100)
- China Scholarship Council (CSC) (201306250114)
- National Institutes of Health (NIH) (8P41 − EB015893, R01 − NS060653)
This publication has 64 references indexed in Scilit:
- A Systematic Comparison of Motion Artifact Correction Techniques for Functional Near-Infrared SpectroscopyFrontiers in Neuroscience, 2012
- Validation of diffuse correlation spectroscopic measurement of cerebral blood flow using phase-encoded velocity mapping magnetic resonance imagingJournal of Biomedical Optics, 2012
- Near-infrared diffuse correlation spectroscopy in cancer diagnosis and therapy monitoringJournal of Biomedical Optics, 2012
- Direct measurement of tissue blood flow and metabolism with diffuse opticsPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2011
- Calibration of diffuse correlation spectroscopy with a time-resolved near-infrared technique to yield absolute cerebral blood flow measurementsBiomedical Optics Express, 2011
- Validation of diffuse correlation spectroscopy measurements of rodent cerebral blood flow with simultaneous arterial spin labeling MRI; towards MRI-optical continuous cerebral metabolic monitoringBiomedical Optics Express, 2010
- Effects of muscle fiber motion on diffuse correlation spectroscopy blood flow measurements during exerciseBiomedical Optics Express, 2010
- Optical measurement of cerebral hemodynamics and oxygen metabolism in neonates with congenital heart defectsJournal of Biomedical Optics, 2010
- Noninvasive Measurement of Cerebral Blood Flow and Blood Oxygenation Using Near-Infrared and Diffuse Correlation Spectroscopies in Critically Brain-Injured AdultsNeurocritical Care, 2009
- Photon Correlation Measurements at Large Lag Times: Improving Statistical AccuracyJournal of Modern Optics, 1988