Red-emission carbon dots as fluorescent “on–off–on” probe for highly sensitive and selective detection of Cu2+ and glutathione
- 5 January 2022
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (6) , 2219-2233
Abstract
A highly sensitive and selective fluorescent “on–off–on” strategy is established for the synchronous detection of Cu2+ and glutathione in aqueous solution. Red carbon dots (R-CDs) were prepared by using precursors of 4,5-difluoro-1,2-phenylenediamine and citric acid via a one-step hydrothermal strategy. R-CDs show a relatively long fluorescence lifetime of 3.47 ns under 455 nm excitation and high absolute fluorescent quantum yield of 20.1% with an excitation wavelength of 550 nm. R-CDs exhibit a marked pH-responsive fluorescence property with no significant perturbation from pH 4 to pH 13 even after five cycles. R-CDs with higher concentration of 750 μg·mL−1 exhibit no significant cytotoxicity and good biocompatibility on HeLa cells and A549 cells after incubation for 48 h. The fluorescence of R-CDs at 619 nm (excited at 550 nm) is quenched statically by Cu2+ and recovered by glutathione subsequently, resulting in a fluorescent “on–off–on” assay for the synchronous detection of Cu2+ and glutathione. Under optimal conditions, the linear response covers the Cu2+ concentration range of 1 to 50 μM and the glutathione concentration range of 1 to 70 μM. Detection limits of Cu2+ and glutathione are 0.16 and 0.41 μM, respectively. This fluorescent probe is applied to the determination of Cu2+ and glutathione in authentic samples with satisfying results. Such an assay broadens the potential application of CDs in environmental areas and clinical therapy fields. Graphical abstractKeywords
This publication has 62 references indexed in Scilit:
- A rapid fluorescence “switch-on” assay for glutathione detection by using carbon dots–MnO2 nanocompositesBiosensors and Bioelectronics, 2015
- A simple fluorescent off–on probe for the discrimination of cysteine from glutathioneChemical Communications, 2015
- Graphene quantum dots as a fluorescent sensing platform for highly efficient detection of copper(II) ionsSensors and Actuators B: Chemical, 2014
- Carbon dots as fluorescent probes for “off–on” detection of Cu2+ and l-cysteine in aqueous solutionBiosensors and Bioelectronics, 2014
- Highly sensitive and selective naked-eye detection of Cu2+ in aqueous medium by a ninhydrin–quinoxaline derivativeSensors and Actuators B: Chemical, 2013
- Functionalized polypyrrole nanotube arrays as electrochemical biosensor for the determination of copper ionsAnalytica Chimica Acta, 2012
- Enhanced Screening of Glutathione-Trapped Reactive Metabolites by In-Source Collision-Induced Dissociation and Extraction of Product Ion Using UHPLC-High Resolution Mass SpectrometryAnalytical Chemistry, 2011
- Sensitive and Selective Sensor for Biothiols in the Cell Based on the Recovered Fluorescence of the CdTe Quantum Dots−Hg(II) SystemAnalytical Chemistry, 2009
- Assessment of human exposure to copper: A case study using the NHEXAS databaseJournal of Exposure Science & Environmental Epidemiology, 2005
- The Role of Copper in Neurodegenerative DiseaseNeurobiology of Disease, 1999