Abstract
This review provides an evidence-based comparison of aqueous shunts in common use. Aqueous shunts are being used with increasing frequency in the surgical management of glaucoma. Recent retrospective studies and prospective clinical trials have compared the outcomes of different shunt designs. Larger end-plate size is associated with greater intraocular pressure (IOP) reduction, but there may be an upper limit beyond which a further increase in plate surface area does not contribute beneficially to pressure control. The biocompatibility of plate material may also influence shunt efficacy. The flow restrictor of the Ahmed glaucoma valve provides an added level of safety by reducing the risk of postoperative hypotony, but this implant also appears to have a higher incidence of bleb encapsulation. Several aqueous shunts are commercially available, and all have been shown to be safe and effective in lowering IOP. Studies comparing aqueous shunts have provided valuable information to assist in surgical decision-making in similar patient groups.Keywords
This publication has 36 references indexed in Scilit:
- Practice Preferences for Glaucoma Surgery: A Survey of the American Glaucoma Society in 2008Ophthalmic Surgery, Lasers and Imaging Retina, 2011
- Treatment Outcomes in the Ahmed Baerveldt Comparison Study after 1 Year of Follow-upOphthalmology, 2011
- The Ahmed Baerveldt Comparison StudyOphthalmology, 2011
- Ahmed Glaucoma Valve and Single-Plate Molteno Implants in Treatment of Refractory Glaucoma: A Comparative StudyAmerican Journal of Ophthalmology, 2010
- Efficacy of the Ahmed S2 Glaucoma Valve Compared with the Baerveldt 250-mm2 Glaucoma ImplantOphthalmology, 2008
- Long-term results of Ahmed glaucoma valve and Molteno implant in neovascular glaucomaEye, 2005
- Comparison of Safety and Efficacy between Silicone and Polypropylene Ahmed Glaucoma Valves in Refractory GlaucomaOphthalmology, 2005
- Intermediate-term outcome of Baerveldt glaucoma implants in Asian eyesOphthalmology, 2003
- Randomized clinical trial of the 350-mm2 versus the 500-mm2 Baerveldt implant: longer term resultsOphthalmology, 1999
- Glaucoma drainage implants in Asian eyesOphthalmology, 1998