Feasability of a Novel Audio-Video Sexual Stimulation System: An Adjunct to the Use of Penile Duplex Doppler Ultrasonography for the Investigation of Erectile Dysfunction
- 1 December 2010
- journal article
- research article
- Published by Oxford University Press (OUP) in The Journal of Sexual Medicine
- Vol. 7 (12) , 3979-3983
Abstract
Penile color Doppler ultrasonography (CDUS) with pharmacotesting has become an important tool for evaluating vascular erectile dysfunction (ED), and audio-visual sexual stimulation (AVSS) has been suggested to be helpful in assisting the performance of CDUS during the examination. To investigate the feasibility of using a novel, remotely controllable AVSS system to assist CDUS. This prospective randomized cross-over study recruited 60 consecutive ED patients. Each patient received three randomized sessions of CDUS under different conditions—AVSS, intracavernous injection (ICI) of alprostadil 20 microgram, or AVSS plus ICI. Clinical responses (rigidity) and penile vascular parameters including peak systolic velocity (PSV), end diastolic velocity (EDV), and resistive index (RI) were measured. At the end of the study, patients were asked about how they perceived the AVSS system in generating sexual arousal. PSV, EDV, RI, and rigidity. Fifty-eight ED patients (aged 21–79) underwent 174 sessions of CDUS. The mean PSV and maximal rigidity of patients under ICI alone were significantly greater than those of patients under AVSS alone (48.25 ± 22.78 vs. 36.54 ± 23.25 cm/second and 65.00 ± 23.93% vs. 43.28 ± 31.79%, respectively; both P < 0.05). The mean PSV of patients under AVSS plus ICI (55.38 ± 28.81 cm/second) was significantly greater than that of patients under ICI alone (P < 0.05), while the mean maximal rigidity (72.50 ± 22.03%) was only marginally greater (P = 0.082). EDV or RI was of no significant difference among the different conditions. Ultrasonographic diagnoses of ED under different conditions varied substantially. Fifty-four (93%) patients considered the AVSS system “very satisfactory” or “satisfactory” in evoking sexual arousal. The novel, remotely controllable AVSS system is well accepted by patients and, in conjunction with ICI, helps to produce higher PSV for patients undergoing CDUS. Kuo YC, Liu SP, Chen JH, Chang HC, Tsai VFS, and Hsieh JT. Feasability of a novel audio-video sexual stimulation system: An adjunct to the use of penile Duplex Doppler Ultrasonography for the investigation of erectile dysfunction.Keywords
This publication has 16 references indexed in Scilit:
- Vascular Impairment of Erection in Patients with Diabetes and Peyronie's Disease: Is that Accumulative?The Journal of Sexual Medicine, 2009
- Cavernous Artery Intima-Media Thickness: A New Parameter in the Diagnosis of Vascular Erectile DysfunctionThe Journal of Sexual Medicine, 2009
- What Kind of Erotic Film Clips Should We Use in Female Sex Research? An Exploratory StudyThe Journal of Sexual Medicine, 2008
- The Role of Penile Color-Duplex Ultrasound for the Evaluation of Erectile DysfunctionThe Journal of Sexual Medicine, 2007
- GENITAL PLUS AUDIOVISUAL SEXUAL STIMULATION FOLLOWING INTRACAVERNOUS VASOACTIVE INJECTION VERSUS RE-DOSING FOR ERECTILE DYSFUNCTION-RESULTS OF A PROSPECTIVE STUDYJournal of Urology, 1998
- The Effect of Intracorporeal Injection Plus Genital and Audiovisual Sexual Stimulation Versus Second Injection on Penile Color Doppler Sonography ParametersJournal of Urology, 1996
- In Vivo Assessment of Trabecular Smooth Muscle Tone, its Application in Pharmaco-Cavernosometry and Analysis of Intracavernous Pressure DeterminantsJournal of Urology, 1995
- Potentiation of drug-induced erection with audiovisual sexual stimulationUrology, 1993
- Duplex Doppler ultrasonography: Noninvasive assessment of penile anatomy and functionSeminars in Roentgenology, 1993
- Vasculogenic impotence evaluated by high-resolution ultrasonography and pulsed Doppler spectrum analysis.Radiology, 1985