Effect of heparin surface modification in reducing silicone oil adherence to various intraocular lenses
Authors:
- Qun PengQPQun Peng
- David J. AppleDADavid J. Apple
- Marcela Escobar-GomezMEMarcela Escobar-Gomez
- Roberto BianchiRBRoberto Bianchi
- Suresh K. PandeySPSuresh K. Pandey
- Liliana WernerLWLiliana Werner
- 1 October 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 27 (10) , 1662-1669
Abstract
To evaluate surface properties of various intraocular lenses (IOLs), including a newly fabricated heparin-surface-modified (HSM) silicone IOL, with special reference to their efficiency in reducing potential silicone oil adherence to the IOL optics. Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. Five groups of rigid and foldable IOLs were analyzed in an in vitro test for the percentage of silicone oil adherence: a single-piece foldable hydrophilic-acrylic IOL (n = 9); a single-piece rigid poly(methyl methacrylate) (PMMA) IOL with HSM coating of the lens optic (n = 9); a 3-piece foldable silicone optic IOL with HSM coating of the optic (n = 10); a single-piece standard rigid PMMA IOL (n = 7); and a standard 3-piece foldable silicone optic IOL (n = 9). After the IOLs were immersed in water and then in silicone oil, gross photographs taken. Image analysis was performed to evaluate the percentage of silicone oil coverage of the anterior and posterior surfaces of each IOL optic. The mean silicone oil coverage of the hydrophilic-acrylic IOLs was 5.6% +/- 2.5% (SD); of the HSM PMMA IOLs, 6.2% +/- 4.3%; of the HSM silicone optic IOLs, 6.7% +/- 3.2%; and of the standard PMMA IOLs, 20.3% +/- 13.3%. The mean silicone oil coverage was greatest on the standard silicone optic IOLs, 98.2% +/- 3.1%. Intraocular lenses with a hydrophilic optic have less tendency toward adherence to silicone oil than more hydrophobic designs. A foldable silicone IOL with heparin surface modification can significantly reduce potential silicone oil adherence, comparable to the level achievable with the rigid HSM PMMA designs. Two new foldable IOL styles, the HSM silicone IOL and IOLs in the general class of hydrophilic-acrylic, were highly efficacious in reducing silicone oil adherence. There is now a real choice of foldable lenses for patients with actual or potential vitreoretinal diseases.Keywords
This publication has 33 references indexed in Scilit:
- Interaktion von Silikonöl mit verschiedenen Intraokularlinsen - Eine licht- und rasterelektronenmikroskopische UntersuchungKlinische Monatsblätter für Augenheilkunde, 1997
- Silicone oil adhesion to intraocular lenses: An experimental study comparing various biomaterialsJournal of Cataract & Refractive Surgery, 1997
- Pathology of silicone intraocular lenses in human eyes obtained postmortemJournal of Cataract & Refractive Surgery, 1995
- The adherence of silicone oil to standard and heparin-coated PMMA intraocular lensesEye, 1994
- Scanning electron microscopic study of modern silicone intraocular lensesJournal of Cataract & Refractive Surgery, 1992
- Surface properties of intraocular lens materials and their influence on in vitro cell adhesionJournal of Cataract & Refractive Surgery, 1991
- Optical resolution of foldable intraocular lensesJournal of Cataract & Refractive Surgery, 1990
- Tissue reaction after silicone and poly(methyl methacrylate) intraocular lens implantation: A light and electron microscopy study in a rabbit modelJournal of Cataract & Refractive Surgery, 1989
- Chemical and Physical Aspects of Clinically Applied Silicones1987
- Clinical and pathologic evaluation of a flexible silicone posterior chamber lens design in a rabbit modelJournal of Cataract & Refractive Surgery, 1986