Abstract
Antibiotics are commonly used in livestock-related agriculture and aquaculture, but they also remain in water and potentially threaten human health. Immunosensors are attractive tools for the rapid detection of antibiotics in water due to their high sensitivity and low costs. However, the simultaneous detection of multi-class antibiotics remains a challenge due to the limited number of detection sites on the immunochip. Also, matrix effects hinder the practical application of these sensors. This paper presents a method for multi-class antibiotic detection in real water using a planar waveguide immunosensor (PWI). We integrate the screening and quantitive detection sites on the same immunochip, and a single screening detection site could detect multi-class antibiotics from the same family, increasing the detection types of analytes. In addition, to eliminate the matrix effects, we develop a testing buffer for real water detection, so that complex pretreatments of the samples can be omitted. Using our sensor and testing buffer, we detect 14 different antibiotics in real water. Lincomycin can be detected with a detection limit of 0.01 μg L−1, and 13 quinolones can be screened in a single assay. These results demonstrate that this planar waveguide immunosensor is capable of simultaneous screening and quantification of multi-class antibiotic pollutants and is expected to be applied for practical environmental monitoring.Keywords
This publication has 40 references indexed in Scilit:
- Development of an indirect competitive ELISA for simultaneous detection of enrofloxacin and ciprofloxacinJournal of Zhejiang University-SCIENCE B, 2011
- Characterization of heavy metals in water and sediments in Taihu Lake, ChinaEnvironmental Monitoring and Assessment, 2011
- Spatial distribution and multiple sources of heavy metals in the water of Chaohu Lake, Anhui, ChinaEnvironmental Monitoring and Assessment, 2011
- A novel chemiluminescence reaction system for the determination of lincomycin with diperiodatonickelate(IV)Microchimica Acta, 2010
- Matrix Effects on the Microcystin-LR Fluorescent Immunoassay Based on Optical BiosensorSensors, 2009
- Heavy metal ions are potent inhibitors of protein foldingBiochemical and Biophysical Research Communications, 2008
- A comprehensive immunoassay for the detection of microcystins in waters based on polyclonal antibodiesAnalytica Chimica Acta, 2006
- The simultaneous separation and determination of five quinolone antibotics using isocratic reversed-phase HPLC: Application to stability studies on an ofloxacin tablet formulationJournal of Pharmaceutical and Biomedical Analysis, 2005
- Development of an optical biosensor assay for detection of β-lactam antibiotics in milk using the penicillin-binding protein 2x*Analytica Chimica Acta, 2004
- Multianalyte effect in the determination of cross-reactivities of pesticide immunoassays in water matricesAnalytica Chimica Acta, 1997