The semi-automatic nucleator
Authors:
- 15 December 2010
- journal article
- Published by Wiley in Journal of Microscopy
- Vol. 242 (2) , 206-215
Abstract
The nucleator is a well-established manual stereological method of estimating mean cell volume from observations on random cell transects through reference points of the cells. In this paper, we present an automated version of the nucleator that uses automatic segmentation of the boundaries of the cell transects. An expert supervises the process. If the segmentation is judged to be satisfactory, an estimate of the cell volume is calculated automatically on the basis of the whole cell transect. In the remaining cases, the expert intervenes and uses the classical nucleator. The resulting estimator is called the semi-automatic nucleator. In this paper, we study the statistical properties of the semi-automatic nucleator. Formulae for the bias and mean square error are derived. The semi-automatic nucleator may have a small bias but will still in most cases be more efficient than the classical nucleator. Procedures for estimating bias and mean square error from a pilot study are provided. The application of the semi-automatic nucleator is illustrated in a study of somatostatin positive inhibitory interneurons which were genetically labelled with green fluorescent protein (GFP). The cells were sampled with an optical disector. The centre of mass in a central cell transect was used as reference point. It is found in this study that the number of cells needed for obtaining, for instance, a 5% precision of the estimate of mean cell volume is 150 and 189 for the semi-automatic and the classical nucleator, respectively. Taking into account that the time spent analysing one cell is shorter for the semi-automatic nucleator than for the classical nucleator, the semi-automatic nucleator is superior to the classical nucleator.Keywords
This publication has 14 references indexed in Scilit:
- Stereology of isolated objects with the invariatorJournal of Microscopy, 2010
- Asymmetric post‐natal development of superior cervical ganglion of paca (Agouti paca)International Journal of Developmental Neuroscience, 2008
- The proportionator: Unbiased stereological estimation using biased automatic image analysis and non-uniform probability proportional to size samplingComputers in Biology and Medicine, 2008
- COMPARATIVE PRECISION OF THE PIVOTAL ESTIMATORS OF PARTICLE SIZEImage Analysis and Stereology, 2008
- A handheld support system to facilitate stereological measurements and mapping of branching structuresJournal of Microscopy, 2007
- A new stereological principle for test lines in three‐dimensional spaceJournal of Microscopy, 2005
- Local Stereology1998
- The nucleatorJournal of Microscopy, 1988
- Particle size‐shape distributions: the general spheroid problem: II. Stochastic model and practical guideJournal of Microscopy, 1978
- Particle size‐shape distributions: The general spheroid problemJournal of Microscopy, 1976