CONTRAST HARMONIC ULTRASOUND OF SPONTANEOUS LIVER NODULES IN 32 DOGS

Authors:

Abstract
Thirty‐two dogs with spontaneous hepatic nodules were given intravenous ultrasound contrast medium (Definity™ or Sonovue™) and imaged with contrast harmonic software on a conventional ultrasound machine system. Digital video images were initially reviewed to describe the perfusion pattern of malignant nodules. The images were reviewed again to test this pattern against all individual nodules. Subjectively, there was improved conspicuity of malignant nodules after contrast enhancement compared with conventional imaging and increased numbers of malignant nodules were often noted. There was decreased conspicuity of benign nodules and no additional nodules were seen after contrast enhancement. There was a highly significant (PP<0.0001) (100%, 94.1%, 93.8%, 100%, and 96.9%, respectively). No complications or morbidity was noted throughout the course of the study. Contrast harmonic ultrasound appears to be accurate at discriminating between naturally occurring benign and malignant nodules in the liver of dogs.

This publication has 27 references indexed in Scilit: