Comparison of dual-energy X-ray absorptiometry, air displacement plethysmography and bioelectrical impedance analysis for the assessment of body composition in morbidly obese women
Authors:
- G BedogniGBG Bedogni
- F AgostiFAF Agosti
- A De ColACA De Col
- N MarazziNMN Marazzi
- A TagliaferriATA Tagliaferri
- A SartorioA Sartorio
- 11 September 2013
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Nutrition
- Vol. 67 (11) , 1129-1132
Abstract
We evaluated the agreement of air displacement plethysmography (ADP) and bioelectrical impedance analysis (BIA) with dual-energy X-ray absorptiometry (DXA) for the assessment of percent fat mass (%FM) in morbidly obese women. Fifty-seven women aged 19-55 years and with a body mass index (BMI) ranging from 37.3 to 55.2 kg/m(2) were studied. Values of %FM were obtained directly from ADP and DXA, whereas for BIA we estimated fat-free mass (FFM) from an equation for morbidly obese subjects and calculated %FM as (weight-FFM)/weight. The mean (s.d.) difference between ADP and DXA for the assessment of %FM was -2.4% (3.3%) with limits of agreement (LOA) from -8.8% to 4.1%. The mean (s.d.) difference between BIA and DXA for the assessment of %FM was 1.7% (3.3%) with LOA from -4.9% to 8.2%. ADP-DXA and BIA-DXA are not interchangeable methods for the assessment of body composition in morbidly obese women.Keywords
This publication has 28 references indexed in Scilit:
- Assessing AdiposityCirculation, 2011
- Development and validation of two equations estimating body composition for overweight and obese postmenopausal womenMaturitas, 2010
- Dual Energy X-Ray Absorptiometry Body Composition Reference Values from NHANESPLOS ONE, 2009
- iDXA, Prodigy, and DPXL Dual-Energy X-ray Absorptiometry Whole-Body Scans: A Cross-Calibration StudyJournal of Clinical Densitometry, 2009
- Comparison of dual-energy X-ray absorptiometry, air displacement plethysmography and bioelectrical impedance analysis for the assessment of body composition in severely obese Caucasian children and adolescentsBritish Journal of Nutrition, 2008
- Assessment methods in human body compositionCurrent Opinion in Clinical Nutrition and Metabolic Care, 2008
- New body fat prediction equations for severely obese patientsClinical Nutrition, 2008
- Cross-validation of bioelectrical impedance analysis for the assessment of body composition in a representative sample of 6- to 13-year-old childrenEuropean Journal of Clinical Nutrition, 2008
- Evaluation of air-displacement plethysmography and bioelectrical impedance analysis vs dual-energy X-ray absorptiometry for the assessment of fat-free mass in elderly subjectsEuropean Journal of Clinical Nutrition, 2007
- Body water distribution in severe obesity and its assessment from eight-polar bioelectrical impedance analysisEuropean Journal of Clinical Nutrition, 2004