Alcohol-Triggered Capillarity through Porous Pyrolyzed Paper-Based Electrodes Enables Ultrasensitive Electrochemical Detection of Phosphate
- 16 August 2021
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 6 (8) , 3125-3132
Abstract
The sensing field has shed light on an urgent necessity for field-deployable, user-friendly, sensitive, and scalable platforms that are able to translate solutions into the real world. Here, we attempt to meet these requests by addressing a simple, low-cost, and fast electrochemical approach to provide sensitive assays that consist of dropping a small volume (0.5 μL) of off-the-shelf alcohols on pyrolyzed paper-based electrodes before adding the sample (150 μL). This method was applied in the detection of phosphate after the formation of the phosphomolybdate complex (250–860 nm in size). Prior drops of isopropanol allow for the fast penetration of the sample through pores of this hydrophobic paper, delivering hindrance-free redox reactions across increasing active areas and ultimately improving the detection performance. The sensitivity (−1.9 10–6 mA cm–2 ppb–1) and limit of detection (1.1 ppb) were improved, respectively, by factors of 33 and 99 over the data achieved without the addition of isopropanol, listing among the lowest values when compared with those results reported in the literature for phosphate (expressed in terms of the concentration of phosphorus). The approach enabled the quantification of this analyte in real samples with accuracies ranging from 87 to 103%. Furthermore, preliminary measurements demonstrated the successful performance of the electrodes with prior addition of other widely used alcohols, that is, methanol and ethanol. These results may extend the applicability of the method. In special, the scalability and eco-friendly character of the electrode fabrication combined with the sensitivity and simplicity of the analyses make the developed platform a promising alternative that may help to pave the way for a new generation of disposable sensors toward the daily monitoring of phosphate in water samples, thus contributing to prevent ecological side effects.Keywords
Funding Information
- Coordena????o de Aperfei??oamento de Pessoal de N??vel Superior (88881.504639/2020-01)
- Petrobras (2018/00363-0)
This publication has 37 references indexed in Scilit:
- Electrochemical Sensors and Biosensors Based on Nanomaterials and NanostructuresAnalytical Chemistry, 2014
- Microemulsification: An Approach for Analytical DeterminationsAnalytical Chemistry, 2014
- Benchmarking Heterogeneous Electrocatalysts for the Oxygen Evolution ReactionJournal of the American Chemical Society, 2013
- Determination of phosphorus in biodiesel using 1:12 phosphomolybdic modified electrode by cyclic voltammetryFuel, 2012
- Phosphate determination in seawater: Toward an autonomous electrochemical methodTalanta, 2011
- Development of an amperometric, screen-printed, single-enzyme phosphate ion biosensor and its application to the analysis of biomedical and environmental samplesSensors and Actuators B: Chemical, 2011
- Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine watersTalanta, 2005
- Investigation of amperometric detection of phosphateTalanta, 2004
- A computational and experimental study of anhydrous phosphotungstic acid and its interaction with water moleculesApplied Catalysis A: General, 2003
- Microelectrode procedures for the determination of silicate and phosphate in waters – fundamental studiesElectroanalysis, 1997