Insights on different analysis techniques in the monothermal and bithermal caloric test – which parameter should we use to quantify vestibular function?
Authors:
- 14 July 2016
- journal article
- research article
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 55 (12) , 730-737
Abstract
Objective: To investigate the use of maximum slow component velocity (MSCV) and time-constant duration (TCd) of elicited nystagmus in quantifying the caloric response and to assess the efficacy of these parameters in the monothermal screening test. Design: Retrospective analysis of caloric results obtained from 150 patients. Bithermal unilateral weakness (UW), directional preponderance (DP), monothermal caloric asymmetry (MCA) based on warm or cool irrigations only, were calculated using both MSCV and TCd. Study sample: 66 males and 84 females, aged 16–88 years (μ = 50, σ = 17), who underwent vestibular assessment. Results: The correlation-coefficient between bithermal caloric unilateral weaknesses calculated using either MSCV or TCd is 0.155 (p < 0.01). Using MSCV and setting significant MCA at 10%, the sensitivity and specificity were respectively 100% and 34% for monothermal warm and 82% and 53% for monothermal cool tests. Using TCd and setting significant MCA at 5%, the sensitivity and specificity were respectively 90% and 77% for monothermal warm and 100% and 74% for monothermal cool tests. Conclusions: In the monothermal warm caloric test, MSCV can be used more reliably than monothermal cool to predict normal bithermal caloric response. The reverse is true if using TCd. Unilateral-weakness calculated using TCd and MSCV were poorly correlated and therefore likely to be demonstrating different aspects of vestibular function.Keywords
This publication has 24 references indexed in Scilit:
- Velocity Storage Contribution to Vestibular Self-Motion Perception in Healthy Human SubjectsJournal of Neurophysiology, 2011
- Validade da prova calórica monotermal em comparação à estimulação bitermalPró-Fono Revista de Atualização Científica, 2010
- Monothermal Caloric Screening Test Performance: A Relative Operating Characteristic Curve AnalysisEar & Hearing, 2009
- Comparison of assessment of caloric nystagmus by observation of duration and by electronystagmo-graphic measurement of slow-phase velocityBritish Journal of Audiology, 1995
- Screening methods for caloric testingClinical Otolaryngology, 1987
- Different time constants for optokinetic and vestibular nystagmus with a single velocity-storage elementBrain Research, 1983
- Clinical evaluation of the hot caloric test as a screening procedureThe Laryngoscope, 1973
- Relation Between Strength Of Stimulus And Nystagmus Frequency In Patients With Menieres DiseaseActa Oto-Laryngologica, 1973
- The value of the hot caloric test.The Laryngoscope, 1965
- STUDIES IN HUMAN VESTIBULAR FUNCTIONBrain, 1942