Alumina ceramic-on-ceramic total hip replacement with a layered acetabular component
Authors:
- 1 July 2006
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 88-B (7) , 877-882
Abstract
A modular layered acetabular component (metal-polyethylene-ceramic) was developed in Japan for use in alumina ceramic-on-ceramic total hip replacement. Between May 1999 and July 2000, we performed 35 alumina ceramic-on-ceramic total hip replacements in 30 consecutive patients, using this layered component and evaluated the clinical and radiological results over a mean follow-up of 5.8 years (5 to 6.5). A total of six hips underwent revision, one for infection, two for dislocation with loosening of the acetabular component, two for alumina liner fractures and one for component dissociation with pelvic osteolysis. There were no fractures of the ceramic heads, and no loosening of the femoral or acetabular component in the unrevised hips was seen at final follow-up. Osteolysis was not observed in any of the unrevised hips. The survivorship analysis at six years after surgery was 83%. The layered acetabular component in our experience, has poor durability because of unexpected mechanical failures including alumina liner fracture and component dissociation.Keywords
This publication has 30 references indexed in Scilit:
- Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture—a case reportActa Orthopaedica, 2006
- Alumina Ceramic Bearings for Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2005
- Intravenous regional administration of corticosteroids in juvenile chronic arthritisActa Orthopaedica, 2004
- Failure of ceramic THR with liner dislocation – a case reportActa Orthopaedica, 2004
- Press-Fit Metal-Backed Alumina SocketsClinical Orthopaedics and Related Research, 2000
- Modern Ceramic-on-Ceramic Total Hip Systems in the United StatesClinical Orthopaedics and Related Research, 2000
- Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patternsThe Journal of Arthroplasty, 2000
- Cementless bulk alumina socketThe Journal of Arthroplasty, 1999
- Ceramic Femoral Head Fractures in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1996
- "Modes of Failure" of Cemented Stem-type Femoral ComponentsClinical Orthopaedics and Related Research, 1979