Abstract
Laboratory tests have shown that current standardized design rules lead to overly optimistic results for calculated ultimate loads of plated structures, especially for internal elements such as box beams. Additionally, the validity of applying equations to compute local buckling resistance might be restricted to steel grades for which the yield strength is less than 500–700 MPa. Both the literature survey and recent experimental buckling tests using ultrahigh-strength steel (UHSS) show that the current design equations can be extended to at least a nominal yield strength of 1,000 MPa. Additionally, a new simplified equation for the reduction factor ρ is proposed and a statistical calculation is presented to compare current and proposed calculation methods.

This publication has 1 reference indexed in Scilit: