Field Analysis of Stepwise Effective Thermal Conductivity along a Borehole Heat Exchanger under Artificial Conditions of Groundwater Flow
Open Access
Abstract
Heat advection caused by groundwater flow can potentially improve the performance of a borehole heat exchanger. However, the required flow velocity is not achieved under most natural conditions. This study focuses on artificial groundwater flow generated by pumping and investigates the associated effect in a lowland area near the Toyohira River alluvial fan, Sapporo, Japan. Thermal response test results are compared under natural and artificial groundwater flow conditions. A pumping well is constructed one meter from the borehole. Temperature profiles are measured in the U-tube during testing, using a pair of optic fiber distributed temperature sensors. The effective thermal conductivity is calculated from the profiles obtained in each 10-m sub-layer; this thermal conductivity is termed the stepwise thermal conductivity. Additionally, the upward flow velocity in the pumping well is measured to estimate the mean groundwater flow velocity at the borehole. The results show that effective thermal conductivity increases at depths less than 50 m, where the pumping creates mean velocities greater than 0.1 m d−1 in each sub-layer (1.5 md−1 on average). Thus, a borehole length of 50 m is more reasonable at the test site for its efficiency in a ground source heat pump system coupled with the pumping well than that used.Keywords
This publication has 18 references indexed in Scilit:
- An appropriate use of the thermal response test for the design of energy foundation piles with U-tube circuitsEnergy and Buildings, 2017
- ESTIMATION OF EFFECTIVE THERMAL CONDUCTIVITIES ACCORDING TO MULTI-LAYERS BY THERMAL RESPONSE TEST WITH A SET OF FIBER OPTICS IN A U-TUBEJournal of Japan Society of Civil Engineers, Ser. G (Environmental Research), 2016
- Stochastic interpretation of thermal response test with TRT-SInterpComputers & Geosciences, 2015
- Finite cylinder-source model for energy pile heat exchangers: Effects of thermal storage and vertical temperature variationsEnergy, 2014
- Borehole Heat Exchangers: heat transfer simulation in the presence of a groundwater flowJournal of Physics: Conference Series, 2014
- Effects of multiple ground layers on thermal response test analysis and ground-source heat pump simulationApplied Energy, 2011
- Numerical analysis of thermal response tests with a groundwater flow and heat transfer modelRenewable Energy, 2011
- Finite line-source model for borehole heat exchangers: effect of vertical temperature variationsGeothermics, 2009
- Numerical evaluation of thermal response testsGeothermics, 2007
- Editorial: Ground-Source Heat Pump System Research—Past, Present, and FutureHVAC&R Research, 2005