Affine Transform to Reform Pixel Coordinates of EOG Signals for Controlling Robot Manipulators Using Gaze Motions
Open Access
- 10 June 2014
- Vol. 14 (6) , 10107-10123
Abstract
Biosignals will play an important role in building communication between machines and humans. One of the types of biosignals that is widely used in neuroscience are electrooculography (EOG) signals. An EOG has a linear relationship with eye movement displacement. Experiments were performed to construct a gaze motion tracking method indicated by robot manipulator movements. Three operators looked at 24 target points displayed on a monitor that was 40 cm in front of them. Two channels (Ch1 and Ch2) produced EOG signals for every single eye movement. These signals were converted to pixel units by using the linear relationship between EOG signals and gaze motion distances. The conversion outcomes were actual pixel locations. An affine transform method is proposed to determine the shift of actual pixels to target pixels. This method consisted of sequences of five geometry processes, which are translation-1, rotation, translation-2, shear and dilatation. The accuracy was approximately 0.86° ± 0.67° in the horizontal direction and 0.54° ± 0.34° in the vertical. This system successfully tracked the gaze motions not only in direction, but also in distance. Using this system, three operators could operate a robot manipulator to point at some targets. This result shows that the method is reliable in building communication between humans and machines using EOGs.Keywords
This publication has 14 references indexed in Scilit:
- Internet browsing application based on electrooculography for disabled peopleExpert Systems with Applications, 2012
- EOG-based visual navigation interface developmentExpert Systems with Applications, 2012
- Alternative communication systems for people with severe motor disabilities: a surveyBioMedical Engineering OnLine, 2011
- A novel eye movement detection algorithm for EOG driven human computer interfacePattern Recognition Letters, 2010
- A new method for calculating eye movement displacement from AC coupled electro-oculographic signals in head mounted eye–gaze input interfacesBiomedical Signal Processing and Control, 2010
- EOG-based Human–Computer Interface system developmentExpert Systems with Applications, 2010
- A low-cost interface for control of computer functions by means of eye movementsComputers in Biology and Medicine, 2007
- Classification of electro-oculogram signals using artificial neural networkExpert Systems with Applications, 2006
- Automated eye tracking system calibration using artificial neural networksComputer Methods and Programs in Biomedicine, 2004
- The effect of small differences in electrode position on EOG signals: application to vigilance studiesElectroencephalography and Clinical Neurophysiology, 1993