Initial Experience with the Gore® Acuseal Graft for Prosthetic Vascular Access
- 30 June 2014
- journal article
- research article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 15 (5) , 385-390
Abstract
Purpose: The purpose of this study is to report the short-term results of the Gore® Acuseal graft for prosthetic vascular access (pVA) in patients with end-stage renal disease on hemodialysis. Methods: Between October 2011 and October 2013, all the consecutive patients who underwent implantation of a new expanded Polytetrafluoroethylene (ePTFE) tri-layer graft were included in the study. Primary and secondary patency rate, time to first cannulation, and complications were recorded. Follow-up was performed at 1, 3, 6, and 12 months after the intervention. Results: Thirty ePTFE tri-layer heparin bonded grafts were implanted in 18 males and 12 females. The graft configuration was radial-basilic (n=12, 40%), brachial-basilic (n=10, 33.3%), femoro-femoral (n=3, 10.0%), radial-cephalic (n=2, 6.7%), radial-antecubital forearm (n=2, 6.7%), and brachial-axillary (n=1, 3.3%). No patient was lost during a mean follow-up time of 6.3±5.9 months (range, 1-24; median, 5). Mean time to first cannulation was 2.4±1.2 days (range, 1-15). Primary functional patency rate was 68.0% ± 10 at 6 and 12 months. Secondary patency rate was 93.3% ± 6 at 6 and 12 months. Pseudoaneurysm, bleeding, seroma, or graft infection was never observed. Conclusions: In our experience, the Gore® Acuseal graft was useful and safe. Early cannulation was always performed, and structural complications did not occur. Primary functional and secondary patency rate are satisfactory in the short term.Keywords
This publication has 36 references indexed in Scilit:
- The natural history of vascular access for hemodialysis: A single center study of 2,422 patientsSurgery, 2009
- Randomized clinical trial comparing decellularized bovine ureter with expanded polytetrafluoroethylene for vascular accessBritish Journal of Surgery, 2009
- Complications of arteriovenous hemodialysis access: Recognition and managementJournal of Vascular Surgery, 2008
- The Society for Vascular Surgery: Clinical practice guidelines for the surgical placement and maintenance of arteriovenous hemodialysis accessJournal of Vascular Surgery, 2008
- Long‐term Outcome of a Cuffed Expanded PTFE Graft for Hemodialysis Vascular AccessWorld Journal of Surgery, 2008
- Autogenous radial-cephalic or prosthetic brachial-antecubital forearm loop AVF in patients with compromised vessels? A randomized, multicenter study of the patency of primary hemodialysis accessJournal of Vascular Surgery, 2005
- Patency Rates and Complications of Exxcel Yarn-Wrapped Polytetrafluoroethylene Grafts Versus Gore-Tex Stretch Polytetrafluoroethylene Grafts: A Prospective StudySurgery Today, 2004
- Prospective, randomized evaluation of a cuffed expanded polytetrafluoroethylene graft for hemodialysis vascular accessSurgery, 2002
- Multicenter evaluation of a polyurethaneurea vascular access graft as compared with the expanded polytetrafluoroethylene vascular access graft in hemodialysis applicationsJournal of Vascular Surgery, 2001
- Comparative Study of Use of Diastat versus Standard Wall PTFE Grafts in Upper Arm Hemodialysis AccessAnnals of Vascular Surgery, 2000