An Aqueous Two-Phase System for the Concentration and Extraction of Proteins from the Interface for Detection Using the Lateral-Flow Immunoassay
Authors:
Open Access
- 10 November 2015
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (11) , e0142654
Abstract
The paper-based immunoassay for point-of-care diagnostics is widely used due to its low cost and portability over traditional lab-based assays. Lateral-flow immunoassay (LFA) is the most well-established paper-based assay since it is rapid and easy to use. However, the disadvantage of LFA is its lack of sensitivity in some cases where a large sample volume is required, limiting its use as a diagnostic tool. To improve the sensitivity of LFA, we previously reported on the concentration of analytes into one of the two bulk phases of an aqueous two-phase system (ATPS) prior to detection. In this study, we preserved the advantages of LFA while significantly improving upon our previous proof-of-concept studies by employing a novel approach of concentrating gold nanoparticles, a common LFA colorimetric indicator. By conjugating specific antibodies and polymers to the surfaces of the particles, these gold nanoprobes (GNPs) were able to capture target proteins in the sample and subsequently be concentrated within 10 min at the interface of an ATPS solution comprised of polyethylene glycol, potassium phosphate, and phosphate-buffered saline. These GNPs were then extracted and applied directly to LFA. By combining this prior ATPS interface extraction with LFA, the detection limit of LFA for a model protein was improved by 100-fold from 1 ng/μL to 0.01 ng/μL. Additionally, we examined the behavior of the ATPS system in fetal bovine serum and synthetic urine to more closely approach real-world applications. Despite using more complex matrices, ATPS interface extraction still improved the detection limit by 100-fold within 15 to 25 min, demonstrating the system’s potential to be applied to patient samples.Keywords
This publication has 22 references indexed in Scilit:
- Developmental Validation of RSID™‐Semen: A Lateral Flow Immunochromatographic Strip Test for the Forensic Detection of Human Semen*Journal of Forensic Sciences, 2011
- Enhanced Sensitivity of Lateral Flow Tests Using a Two-Dimensional Paper Network FormatAnalytical Chemistry, 2011
- Nanoparticle PEGylation for Imaging and TherapyNanomedicine, 2011
- Enhancing the lateral-flow immunoassay for viral detection using an aqueous two-phase micellar systemAnalytical and Bioanalytical Chemistry, 2010
- Quantifying Colorimetric Assays in Paper-Based Microfluidic Devices by Measuring the Transmission of Light through PaperAnalytical Chemistry, 2009
- Low Sensitivity of Rapid Diagnostic Test for InfluenzaClinical Infectious Diseases, 2009
- Enabling a microfluidic immunoassay for the developing world by integration of on-card dry reagent storageLab on a Chip, 2008
- Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable BioassaysAngewandte Chemie International Edition, 2007
- Urinary protein isolation by high-performance ion exchange chromatographyJournal of Chromatography A, 1983
- Partition of Cell Particles and Macromolecules in Polymer Two-Phase Systems1970