FATIGUE UNDER CYCLIC COMPRESSIVE LOAD
Authors:
- 1 October 1984
- journal article
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 7 (4) , 279-284
Abstract
For ultra‐high strength steels and aluminium alloys, a fatigue crack could initiate from a notch tip under cyclic compressive load. The threshold value for fatigue crack initiation under compressive load can be as great as four times that under tensile load. The crack grew at a decreasing rate until eventually it stopped growing altogether under cyclic compressive load with a maximum length of 0.2‐0.5 mm. If the minimum compressive load was near zero, i.e. compression to zero load cycling, the threshold value was near that under tensile loading and the compressive fatigue crack could continue to grow; however, the crack growth rate under compression to zero load fatigue was 10–100 times less than that under the tensile fatigue loading.Keywords
This publication has 6 references indexed in Scilit:
- Stress Corrosion Cracking of Austenitic Stainless Steel Under Compressive StressCorrosion, 1984
- Hydrogen Induced Delayed Cracking of Type III Steel SpecimensCorrosion, 1982
- Effect of Hydrogen on the Apparent Yield Stress—Research on the Cause of Hydrogen Induced Delayed PlasticityCorrosion, 1981
- Mechanism of Stress Corrosion Cracking of Low Alloy Steel in WaterCorrosion, 1981
- Mechanism of Stress Corrosion Cracking of Steels in H2SCorrosion, 1980
- FATIGUE IN COMPRESSIONFatigue & Fracture of Engineering Materials & Structures, 1979