Clinical and Haemodynamic Outcomes in Small Versus Large Prostheses in Surgical Aortic Valve Replacement: A Systematic Review and Meta‐Analysis
Authors:
- Joshua J. HonJoshua J. Hon
- Arian Arjomandi RadARArian Arjomandi Rad
- Odhran HarbinsonOHOdhran Harbinson
- Fadi Al-ZubaidiFAFadi Al-Zubaidi
- Peyman Sardari NiaPNPeyman Sardari Nia
- Rana SayeedRSRana Sayeed
- Vivek SrivastavaVSVivek Srivastava
- Antonios KourliourosAKAntonios Kourliouros
- Thanos AthanasiouTAThanos Athanasiou
Open Access
- 1 January 2026
- journal article
- review article
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 2026 (1)
Abstract
Objectives: This systematic review and meta‐analysis evaluate clinical and haemodynamic outcomes between small (≤ 21 mm) and large (≥ 23 mm) prosthetic valves in surgical aortic valve replacement (SAVR). Methods: A comprehensive literature search was conducted from inception to March 2025. Studies comparing outcomes between small and large aortic valve prostheses were included. Primary outcome was all‐cause mortality. Secondary outcomes included short‐term mortality, stroke, reoperation, endocarditis, haemodynamic parameters and patient‐prosthesis mismatch (PPM). Random‐effects models calculated pooled risk ratios (RRs) or mean differences (MDs). Mediation analysis explored the relationships between prosthesis size, PPM and mortality. Results: Twelve studies comprising 9896 patients were included. Small prostheses were associated with increased all‐cause mortality (RR 1.23, 95% CI 1.07–1.41, p = 0.004) and short‐term mortality (RR 1.73, 95% CI 1.11–2.68, p = 0.015). No significant differences were observed for stroke, reoperation or endocarditis. Small prostheses demonstrated significantly lower indexed effective orifice area (MD −0.13 cm 2 /m 2 , 95% CI ‐0.24 to −0.01, p = 0.030) and higher incidence of PPM (RR 2.02, 95% CI 1.36–3.00, p < 0.0001). Mediation analysis revealed a strong correlation ( r = 0.904) between PPM and all‐cause mortality effect sizes. Very small prostheses (< 19 mm) exhibited elevated mean gradients (20.8 mmHg) and substantial PPM incidence (33.2%). Conclusions: Small aortic valve prostheses are associated with increased mortality and PPM. The strong correlation between PPM and mortality effects suggests PPM may be the key mechanism underlying adverse outcomes. Alternative strategies such as root enlargement may be warranted in patients requiring small prostheses.Keywords
This publication has 28 references indexed in Scilit:
- Calcific Aortic StenosisJAMA, 2024
- Aortic Stenosis, Heart Failure, and Aortic Valve ReplacementJAMA Cardiology, 2024
- Age-Stratified Surgical Aortic Valve Replacement for Aortic StenosisThe Annals of Thoracic Surgery, 2024
- Impact of Aortic Root Enlargement on Patients Undergoing Aortic Valve ReplacementThe Annals of Thoracic Surgery, 2022
- Essential Information on Surgical Heart Valve Characteristics for Optimal Valve Prosthesis Selection: Expert Consensus Document From the European Association for Cardio-Thoracic Surgery (EACTS)–The Society of Thoracic Surgeons (STS)–American Association for Thoracic Surgery (AATS) Valve Labelling Task ForceThe Annals of Thoracic Surgery, 2021
- Aortic Root Enlargement Is Safe and Reduces the Incidence of Patient-Prosthesis Mismatch: A Meta-analysis of Early and Late OutcomesCanadian Journal of Cardiology, 2019
- Impact of Annular Size on Outcomes After Surgical or Transcatheter Aortic Valve ReplacementThe Annals of Thoracic Surgery, 2018
- Prolonged Cross-Clamping During Aortic Valve Replacement Is an Independent Predictor of Postoperative Morbidity and Mortality: Analysis of the Japan Cardiovascular Surgery DatabaseThe Annals of Thoracic Surgery, 2017
- Impact of Valve Prosthesis-Patient Mismatch on Left Ventricular Mass Regression Following Aortic Valve ReplacementThe Annals of Thoracic Surgery, 2005
- Quantifying heterogeneity in a meta‐analysisStatistics in Medicine, 2002