High-angular-resolution diffusion-weighted imaging (HARDI) MRI acquisitions have become common for use with higher order models of diffusion. Despite successes in resolving complex fiber configurations and probing microstructural properties of brain tissue, there is no common consensus on the optimal b-value and number of diffusion directions to use for these HARDI methods. While this question has been addressed by analysis of the diffusion-weighted signal directly, it is unclear how this translates to the information and metrics derived from the HARDI models themselves. Using a high angular resolution data set acquired at a range of b-values, and repeated 11 times on a single subject, we study how the b-value and number of diffusion directions impacts the reproducibility and precision of metrics derived from Q-ball imaging, a popular HARDI technique. We find that Q-ball metrics associated with tissue microstructure and white matter fiber orientation are sensitive to both the number of diffusion directions and the spherical harmonic representation of the Q-ball, and often are biased when under sampled. These results can advise researchers on appropriate acquisition and processing schemes, particularly when it comes to optimizing the number of diffusion directions needed for metrics derived from Q-ball imaging.Keywords
This publication has 10 references indexed in Scilit:
- NMR in Biomedicine2016
- An integrated approach to correction for off-resonance effects and subject movement in diffusion MR imagingNeuroImage, 2016
- Magnetic Resonance in Medicine2016
- Investigating the prevalence of complex fiber configurations in white matter tissue with diffusion magnetic resonance imagingHuman Brain Mapping, 2012
- Evaluation of the accuracy and angular resolution of q-ball imagingNeuroImage, 2008
- Effects of diffusion weighting schemes on the reproducibility of DTI-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5TNeuroImage, 2007
- Multiple‐Fiber Reconstruction Algorithms for Diffusion MRIAnnals of the New York Academy of Sciences, 2005
- How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imagingNeuroImage, 2003
- Persistent angular structure: new insights from diffusion magnetic resonance imaging dataInverse Problems, 2003
- Estimation of the Effective Self-Diffusion Tensor from the NMR Spin EchoJournal of Magnetic Resonance, Series B, 1994