Large-area silicon drift detectors for new applications in nuclear medicine imaging
Authors:
- J. EngdahlJEJ. Engdahl
- W. RossnerWRW. Rossner
- O. BoslauOBO. Boslau
- J. KemmerJKJ. Kemmer
- 16 August 2004
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 51 (4) , 1631-1635
Abstract
In this paper, we have investigated the performance of a large-area (1 cm/sup 2/) square-shaped silicon drift detector (SDD) operating as an X-ray detector in direct conversion mode, as well as a photodetector in combination with a single crystal CsI:Tl scintillator (10 mm /spl times/ 10 mm /spl times/ 7 mm). An external FET, along with a low-noise charge sensitive preamplifier, was used for testing the prototype detector in the temperature range of -50 to +26/spl deg/C. In direct conversion mode, the SDD exhibited an energy resolution of 195 eV FWHM (at 5.9 keV, -23.5/spl deg/C, 4 /spl mu/s shaping time) and 170 eV FWHM (at 5.9 keV, -50/spl deg/C, 8 /spl mu/s shaping time). Pulse height spectra and signal rise times were recorded at different X-ray interaction locations across the SDD surface with the aid of a moveable collimator. Depending on collimator position, we measured signal rise times between 100 and 750 ns. After coupling the CsI-scintillator directly to the SDD surface, we obtained an excellent energy resolution of 7.0% FWHM with an uncollimated /sup 57/Co source (122 keV, -10/spl deg/C, 12 /spl mu/s shaping time). At -23.5/spl deg/C, we measured a signal rise time of approximately 25 /spl mu/s for this scintillator-SDD unit. Using a pulsed LED as excitation source, we were able to evaluate the electron drift characteristics of the tested SDD and to identify the temporal behavior of the CsI:Tl scintillator to be the dominant component of this long rise time. A short analysis regarding the different SDD signal rise times with and without scintillator will be presented.Keywords
This publication has 10 references indexed in Scilit:
- Temperature dependence of absolute CsI(Tl) scintillation yield2002
- Detectors for high-resolution gamma-ray imaging based on a single CsI(Tl) scintillator coupled to an array of silicon drift detectorsIEEE Transactions on Nuclear Science, 2001
- Silicon drift detectors for high count rate X-ray spectroscopy at room temperatureNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- First prototype of a gamma-camera based on a single CsI:(Tl) scintillator coupled to a silicon drift detector arrayIEEE Transactions on Nuclear Science, 2000
- Room-temperature x- and gamma-ray spectroscopy with silicon drift detectors2000
- Silicon drift detectors as radiation monitors for x rays, gamma rays, and particles2000
- Fast-timing silicon photodetectorsIEEE Transactions on Nuclear Science, 2000
- Large area silicon drift detectors for X-rays-new resultsIEEE Transactions on Nuclear Science, 1999
- Temperature dependence of CsI (T1) absolute scintillation yieldIEEE Transactions on Nuclear Science, 1993
- Temperature dependence of CsI(Tl) gamma-ray excited scintillation characteristicsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993