Changes to medication-use processes after overdose of U-500 regular insulin
Authors:
- 1 December 2012
- journal article
- case report
- Published by Oxford University Press (OUP) in American Journal of Health-System Pharmacy
- Vol. 69 (23) , 2089-2093
Abstract
Purpose Modifications made to medication-use processes after an overdose of U-500 regular insulin are described. Summary After a medication error occurred with U-500 regular insulin, a multidisciplinary team of physicians, nurses, advanced-practice nurses, and pharmacists was created to review and improve the ordering, dispensing, and administration processes associated with U-500 regular insulin. The group determined that current safety practices for managing insulin were inadequate. New safety processes specific to U-500 regular insulin were developed and implemented. Vials of U-500 regular insulin are no longer dispensed to nursing units and are stored only in the pharmacy and separated from other insulins. The ordering of U-500 regular insulin is limited to the endocrinology service, and all orders are written using a specialized U-500 regular insulin order set. The option for i.v. administration for U-500 regular insulin was removed from the pharmacy order-entry system; thus, only the subcutaneous route is entered by the pharmacist. In addition, patient-specific doses of U-500 regular insulin are prepared in the pharmacy using only tuberculin syringes that require a double check by two pharmacists. These syringes are delivered to patient care areas in a bag distinguishing the medication as “high alert.” One last safety check involving a two-nurse check at the bedside to confirm correct medication administration is performed. Lastly, patient education material specifically for U-500 regular insulin is available online. Conclusion A multidisciplinary team recommended modifications to the medication-use system regarding U-500 regular insulin after review of a medication error. No errors involving U-500 regular insulin have been reported since implementation of the changes.Keywords
This publication has 7 references indexed in Scilit:
- Addressing safety concerns about U-500 insulin in a hospital settingAmerican Journal of Health-System Pharmacy, 2011
- Use of concentrated insulin human regular (U-500) for patients with diabetesAmerican Journal of Health-System Pharmacy, 2010
- Pharmacists’ role in ensuring safe and effective hospital use of insulinAmerican Journal of Health-System Pharmacy, 2010
- High-dose Insulin Therapy: is it Time for U-500 Insulin?Endocrine Practice, 2009
- Clinical Experience With U-500 Regular Insulin in Obese, Markedly Insulin-Resistant Type 2 Diabetic PatientsDiabetes Care, 2006
- Intensive Insulin Therapy in the Medical ICUNew England Journal of Medicine, 2006
- Intensive Insulin Therapy in Critically Ill PatientsNew England Journal of Medicine, 2001