Suspected invasive placenta: evaluation with magnetic resonance imaging
Authors:
- Laurence BourLBLaurence Bour
- Vinciane PlacéVPVinciane Placé
- Sandra BendavidSBSandra Bendavid
- Yann FargeaudouYFYann Fargeaudou
- Jean-Jacques PortalJPJean-Jacques Portal
- Aude RicbourgARAude Ricbourg
- Delphine SebbagDSDelphine Sebbag
- Anthony DohanADAnthony Dohan
- Eric VicautEVEric Vicaut
- Philippe SoyerPSPhilippe Soyer
- 29 July 2014
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 24 (12) , 3150-3160
Abstract
To determine the utility of magnetic resonance imaging (MRI) in diagnosing invasive placenta (IP). MRI findings in 32 women with suspected IP were evaluated independently by four readers. Interobserver agreement was calculated with kappa (κ) statistics. Associations between MRI findings and IP were assessed by univariate and multivariate analyses. Sensitivity, specificity and accuracy of MRI for the diagnosis of IP were estimated. Sixteen women (16/32; 50 %) had confirmed IP. Interobserver correlation for the diagnosis of IP was fair (κ = 0.40). Univariate analysis revealed that thinning or focal defect of the uteroplacental interface (P < 0.0001) was the most discriminating MRI variable in the differentiation between normal and IP. Overall sensitivity and specificity of MRI for the diagnosis of IP were 84 % [95 % CI: 75–94 %] and 80 % [95 % CI: 66–93 %], respectively. Thinning or focal defect of the uteroplacental interface was the most accurate finding (88 %) in the diagnosis of IP. Multivariate analysis revealed that thinning or focal defect of the uteroplacental interface was the single independent predictor of IP (P = 0.0006; OR = 64.99). MR imaging has 84 % sensitivity [95 % CI: 75–94 %] and 80 % specificity [95 % CI: 66–93 %] for the diagnosis of IP. Thinning or focal defect of the uteroplacental interface is the most discriminating independent MR variable in differentiating between normal placenta and IP. • MR imaging has acceptable degrees of accuracy to diagnose invasive placenta. • Focal uteroplacental interface defect is the best finding to diagnose invasive placenta. • Focal uteroplacental interface defect is the single independent predictor of invasive placenta.Keywords
This publication has 34 references indexed in Scilit:
- MR imaging of the placenta: what a radiologist should knowAbdominal Radiology, 2012
- Utility of Ultrasound and MRI in Prenatal Diagnosis of Placenta Accreta: A Pilot StudyAmerican Journal of Roentgenology, 2011
- MRI of Placenta Accreta: A New Imaging PerspectiveAmerican Journal of Roentgenology, 2011
- Long-term psychological impact of severe postpartum hemorrhageActa Obstetricia et Gynecologica Scandinavica, 2011
- Fertility and pregnancy outcomes following conservative treatment for placenta accretaHuman Reproduction, 2010
- Effect of Predelivery Diagnosis in 99 Consecutive Cases of Placenta AccretaObstetrics & Gynecology, 2010
- Optimal management strategies for placenta accretaBJOG: An International Journal of Obstetrics & Gynaecology, 2009
- Placenta Previa, Placenta Accreta, and Vasa PreviaObstetrics & Gynecology, 2006
- Magnetic resonance imaging in 300 cases of placenta accreta: surgical correlation of new findingsActa Obstetricia et Gynecologica Scandinavica, 2005
- Abnormal placentation: Twenty-year analysisAmerican Journal of Obstetrics and Gynecology, 2005