Real-Time Fault Detection to Ensure the Safe Operation of the Single-Phase Five-Level VIENNA Rectifier
Open Access
Abstract
This work aims to explore and evaluate the nonreversible AC/DC five-level structure from the point of view of its operational safety: high electrical security on internal destruction and continuity in operation. It only has low-voltage monotransistor cells (Si and SiC 600 V max) and is intrinsically tolerant to imperfection control and parasites, therefore naturally secure. The design and lab-test of fault monitoring and fault diagnosis with just one voltage sensor of a single-phase five-level VIENNA rectifier were proposed. This real-time diagnostic method allows for a safe stop or corrective control strategy based on the reconfiguration of the modulation. The reconstruction strategy allows for optimization of the current and voltage signals as well as power factor. A continuous post-fault operation can be achieved for critical applications. An experimental prototype 3 kW/230 VAC/800 VDC/32 kHz was created to validate the proposed fault diagnosis method and reconfiguration control method.Keywords
Funding Information
- Vietnam Academy of Science and Technology (VAST0705/19-20)
This publication has 32 references indexed in Scilit:
- Reduction of Input Current Harmonic Distortions and Balancing of Output Voltages of the Vienna Rectifier Under Supply Voltage DisturbancesIEEE Transactions on Power Electronics, 2016
- Logic-Based Methods for Intelligent Fault Diagnosis and Recovery in Power ElectronicsIEEE Transactions on Power Electronics, 2016
- Performance Analysis of Carrier-Based Discontinuous PWM Method for Vienna Rectifiers With Neutral-Point Voltage BalanceIEEE Transactions on Power Electronics, 2015
- Online Inverter Fault Diagnosis of Buck-Converter BLDC Motor CombinationsIEEE Transactions on Power Electronics, 2014
- An Open-Switch Fault Detection Method and Tolerance Controls Based on SVM in a Grid-Connected T-Type Rectifier With Unity Power FactorIEEE Transactions on Industrial Electronics, 2014
- Design and Performance Evaluation of Overcurrent Protection Schemes for Silicon Carbide (SiC) Power MOSFETsIEEE Transactions on Industrial Electronics, 2014
- Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter SystemIEEE Transactions on Power Electronics, 2011
- $V_{CE}$ Sensing for IGBT Protection in NPC Three Level Converters—Causes For Spurious Trippings and Their EliminationIEEE Transactions on Power Electronics, 2010
- Intelligent diagnosis of open and short circuit faults in electric drive inverters for real-time applicationsIET Power Electronics, 2010
- A Review of Three-Phase Improved Power Quality AC–DC ConvertersIEEE Transactions on Industrial Electronics, 2004