Non‐enzymatic hydrogen peroxide sensor based on palladium‐decorated poly(thionine) modified glassy carbon electrode
- 1 April 2024
- journal article
- research article
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 71 (5) , 482-492
Abstract
Glassy carbon electrode was modified with palladium‐decorated conducting poly(thionine) film to develop a simple, cost‐effective, and fast amperometric sensor for the detection of H2O2. Conducting PTH film served as a porous and stable support matrix for even distribution of the Pd nanomaterials. In order to get the maximum performance from the modified electrode system, experimental conditions were optimized using chronoamperometry. The Pd/PTH@GCE electrode showed maximum performance in buffer solution at pH = 7.5 meaning it is suitable for the detection of H2O2 at physiological pH (7.4). Scanning Electron Microscopy was performed for physical characterization of the modified electrodes using pencil graphite electrodes. The active surface area for Pd/PTH‐modified GCE was calculated as 1.103 cm2. The linear concentration range was determined as 0.2–7.0 mM and its sensitivity was determined as 40.0 μA mM−1. The detection limit (LOD) of the sensor was calculated as 12.3 μM with a signal/noise ratio of 3.Keywords
This publication has 44 references indexed in Scilit:
- Enhanced electrocatalytic activity of palladium electrocatalysts supported on corncob biochar for ethanol oxidation reaction in alkaline mediumJournal of the Chinese Chemical Society, 2024
- Two silver(I) complexes: Synthesis, structures, and electrochemicalH2O2sensingJournal of the Chinese Chemical Society, 2022
- A flexible and highly selective non-enzymatic H2O2 sensor based on silver nanoparticles embedded into NafionApplied Surface Science, 2019
- A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxideMicrochimica Acta, 2015
- Synthesis of Functionalized MWCNTs Decorated with Copper Nanoparticles and Its Application as a Sensitive Sensor for Amperometric Detection of H2O2Electroanalysis, 2015
- Hydrogen peroxide biosensor based on gold nanoparticles/thionine/gold nanoparticles/multi-walled carbon nanotubes–chitosans composite film-modified electrodeApplied Surface Science, 2012
- Amperometric Biosensors2011
- Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticlesMicrochimica Acta, 2011
- Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticlesMicrochimica Acta, 2011
- Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorodsMicrochimica Acta, 2011