Abstract
Patient warming has become a standard of care for the prevention of unintentional hypothermia based on benefits established in general surgery. However, these benefits may not fully translate to contamination-sensitive surgery (i.e., implants), because patient warming devices release excess heat that may disrupt the intended ceiling-to-floor ventilation airflows and expose the surgical site to added contamination. Therefore, we studied the effects of 2 popular patient warming technologies, forced air and conductive fabric, versus control conditions on ventilation performance in an orthopedic operating room with a mannequin draped for total knee replacement. Ventilation performance was assessed by releasing neutrally buoyant detergent bubbles ("bubbles") into the nonsterile region under the head-side of the anesthesia drape. We then tracked whether the excess heat from upper body patient warming mobilized the "bubbles" into the surgical site. Formally, a randomized replicated design assessed the effect of device (forced air, conductive fabric, control) and anesthesia drape height (low-drape, high-drape) on the number of bubbles photographed over the surgical site. The direct mass-flow exhaust from forced air warming generated hot air convection currents that mobilized bubbles over the anesthesia drape and into the surgical site, resulting in a significant increase in bubble counts for the factor of patient warming device (P < 0.001). Forced air had an average count of 132.5 versus 0.48 for conductive fabric (P = 0.003) and 0.01 for control conditions (P = 0.008) across both drape heights. Differences in average bubble counts across both drape heights were insignificant between conductive fabric and control conditions (P = 0.87). The factor of drape height had no significant effect (P = 0.94) on bubble counts. Excess heat from forced air warming resulted in the disruption of ventilation airflows over the surgical site, whereas conductive patient warming devices had no noticeable effect on ventilation airflows. These findings warrant future research into the effects of forced air warming excess heat on clinical outcomes during contamination-sensitive surgery.Keywords
This publication has 18 references indexed in Scilit:
- Effect of forced‐air warming on the performance of operating theatre laminar flow ventilation*Anaesthesia, 2012
- Does the use of laminar flow and space suits reduce early deep infection after total hip and knee replacement?The Journal of Bone and Joint Surgery. British volume, 2011
- Energy efficiency comparison of forced-air versus resistance heating devices for perioperative hypothermia managementEnergy, 2010
- Forced-air warming: technology, physical background and practical aspectsCurrent Opinion in Anaesthesiology, 2009
- Operating Room Ventilation With Laminar Airflow Shows No Protective Effect on the Surgical Site Infection Rate in Orthopedic and Abdominal SurgeryAnnals of Surgery, 2008
- Deep Infection After Total Knee Replacement: Impact of Laminar Airflow Systems and Body Exhaust Suits in the Modern Operating RoomInfection Control & Hospital Epidemiology, 2007
- Guideline for Prevention of Surgical Site Infection, 1999American Journal of Infection Control, 1999
- Air, antibiotics and sepsis in replacement jointsJournal of Hospital Infection, 1988
- Ultraclean air and antibiotics for prevention of postoperative infection: A multicenter study of 8,052 joint replacement operationsActa Orthopaedica, 1987
- The effect of obstructions and thermals in laminar-flow systemsEpidemiology and Infection, 1974