SUV-quantification of physiological lung tissue in an integrated PET/MR-system: Impact of lung density and bone tissue
Open Access
- 31 May 2017
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (5) , e0177856
Abstract
The aim of the study was to investigate the influence of lung density changes as well as bone proximity on the attenuation correction of lung standardized uptake values (SUVs). 15 patients with mostly oncologic diseases were examined in 18F-FDG-PET/CT and subsequently in a fully integrated PET/MR scanner. From each PET dataset acquired in PET/MR, four different PET reconstructions were computed using different attenuation maps (μ-maps): i) CT-based μ-map (gold standard); ii) CT-based μ-map in which the linear attenuation coefficients (LAC) of the lung tissue was replaced by the lung LAC from the MR-based segmentation method; iii) based on reconstruction ii), the LAC of bone structures was additionally replaced with the LAC from the MR-based segmentation method; iv) the vendor-provided MR-based μ-map (segmentation-based method). Those steps were performed using MATLAB. CT Hounsfield units (HU) and SUVmean was acquired in different levels and regions of the lung. Relative differences between the differently corrected PETs were computed. Compared to the gold standard, reconstruction ii), iii) and iv) led to a relative underestimation of SUV in the posterior regions of -9.0%, -13.4% and -14.0%, respectively. Anterior and middle regions were less affected with an overestimation of about 6–8% in reconstructions ii)–iv). It could be shown that both, differences in lung density and the vicinity of bone tissue in the μ-map may have an influence on SUV, mostly affecting the posterior lung regions.Keywords
This publication has 36 references indexed in Scilit:
- MRI for attenuation correction in PET: methods and challengesMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Challenges and current methods for attenuation correction in PET/MRMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based MethodsJournal of Nuclear Medicine, 2011
- elastix: A Toolbox for Intensity-Based Medical Image RegistrationIEEE Transactions on Medical Imaging, 2009
- From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid TumorsJournal of Nuclear Medicine, 2009
- MRI of the lung: Value of different turbo spin‐echo, single‐shot turbo spin‐echo, and 3D gradient‐echo pulse sequences for the detection of pulmonary metastasesJournal of Magnetic Resonance Imaging, 2006
- Vergleich verschiedener Atem- und Kontrastmittelprotokolle bezüglich Bild- und Koregistrierungsqualität bei 18F-FDG-PET/CT-UntersuchungenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2006
- X-ray-based attenuation correction for positron emission tomography/computed tomography scannersSeminars in Nuclear Medicine, 2003
- Measurement of Lung Density by Means of Quantitative CT ScanningChest, 1992
- Body Position Changes Redistribute Lung Computed-Tomographic Density in Patients with Acute Respiratory FailureAnesthesiology, 1991