MALTA-Cz: A radiation hard full-size monolithic CMOS sensor with small electrodes on high-resistivity Czochralski substrate
Authors:
- H. PerneggerHPH. Pernegger
- P. AllportPAP. Allport
- D. V. BerleaDBD. V. Berlea
- A. BirmanABA. Birman
- D. BortolettoDBD. Bortoletto
- C. ButtarCBC. Buttar
- E. CharbonECE. Charbon
- F. DachsFDF. Dachs
- V. DaoVDV. Dao
- H. DenizliHDH. Denizli
- M. DyndalMDM. Dyndal
Preprint
Abstract
Depleted Monolithic Active Pixel Sensor (DMAPS) sensors developed in the Tower Semiconductor 180 nm CMOS imaging process have been designed in the context of the ATLAS ITk upgrade Phase-II at the HL-LHC and for future collider experiments. The ``MALTA-Czochralski (MALTA-Cz)'' full size DMAPS sensor has been developed with the goal to demonstrate a radiation hard, thin CMOS sensor with high granularity, high hit-rate capability, fast response time and superior radiation tolerance. The small pixel size ($36.4\times 36.4$~$\mu$m$^2$) provides high spatial resolution. Its asynchronous readout architecture is designed for high hit-rates and fast time response in triggered and trigger-less detector applications. The readout architecture is designed to stream all hit data to the multi-channel output which allows an off-sensor trigger formation and the use of hit-time information for event tagging. The sensor manufacturing has been optimised through process adaptation and special implant designs to allow the manufacturing of small electrode DMAPS on thick high-resistivity p-type Czochralski substrate. The special processing ensures excellent charge collection and charge particle detection efficiency even after a high level of radiation. Furthermore the special implant design and use of a Czochralski substrate improves the sensor's time resolution. This paper presents a summary of sensor design optimisation through process and implant choices and TCAD simulation to model the signal response. Beam and laboratory test results on unirradiated and irradiated sensors have shown excellent detection efficiency after a dose of $2\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$. The time resolution of the sensor is measured to be $\sigma=2$~ns.
Keywords
All Related Versions
This publication has 20 references indexed in Scilit:
- Studies for low mass, large area monolithic silicon pixel detector modules using the MALTA CMOS pixel chipNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021
- Radiation hard monolithic CMOS sensors with small electrodes for High Luminosity LHCNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021
- Computational analysis of the dose rates at JSI TRIGA reactor irradiation facilitiesApplied Radiation and Isotopes, 2017
- A process modification for CMOS monolithic active pixel sensors for enhanced depletion, timing performance and radiation toleranceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2017
- Neutron irradiation test of depleted CMOS pixel detector prototypesJournal of Instrumentation, 2017
- General broken lines as advanced track fitting methodNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012
- Computational analysis of irradiation facilities at the JSI TRIGA reactorApplied Radiation and Isotopes, 2012
- A TCT and annealing study on Magnetic Czochralski silicon detectors irradiated with neutrons and 24 GeV/c protonsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Radiation damage in p-type silicon irradiated with neutrons and protonsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- The origin of double peak electric field distribution in heavily irradiated silicon detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002