The effect of acetabular cup size on the short-term stability of revision hip arthroplasty: A finite element investigation
Authors:
- A.T.M. PhillipsAPA.T.M. Phillips
- Pankaj PankajPPPankaj Pankaj
- A S UsmaniAUA S Usmani
Open Access
- 1 April 2004
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 218 (4) , 239-249
Abstract
The study uses idealized two-dimensional finite element models to examine the behaviour of the acetabular construct following revision hip arthroplasty, carried out using the Slooff-Ling impaction grafting technique. The behaviour of bone graft was considered in detail, with non-linear elasticity and non-associated plasticity being adopted. Load was applied to the acetabular construct through a femoral head using smooth sliding surfaces. In particular, four models were subjected to two idealized cyclic load cases to investigate the effect of acetabular cup size on the short-term stability of the acetabular construct. The study suggests that benefits may be gained by using the largest practical size of acetabular cup.Keywords
This publication has 32 references indexed in Scilit:
- TECHNIQUES TO IMPROVE THE SHEAR STRENGTH OF IMPACTED BONE GRAFTJournal of Bone and Joint Surgery, 2003
- Hip contact forces and gait patterns from routine activitiesJournal of Biomechanics, 2001
- Cemented total hip arthroplasty with autogenous acetabular bone grafting for hips with developmental dysplasia in adultsThe Journal of Bone and Joint Surgery. British volume, 2000
- Glenoid cancellous bone strength and modulusJournal of Biomechanics, 1999
- Mechanical considerations in impaction bone graftingThe Journal of Bone and Joint Surgery. British volume, 1999
- Acetabular reconstruction with impacted morsellised cancellous bone graft and cement. A 10- to 15-year follow-up of 60 revision arthroplasties.The Journal of Bone and Joint Surgery. British volume, 1998
- Loss of bone stock with cementless hip arthroplastyThe Journal of Arthroplasty, 1995
- Hip joint loading during walking and running, measured in two patientsJournal of Biomechanics, 1993
- Finite element analysis of acetabular reconstruction: Noncemented threaded cupsActa Orthopaedica, 1987
- Bone grafting in total hip replacement for acetabular protrusionActa Orthopaedica, 1984