Evaluation of 24‐Hour Arterial Stiffness Indices and Central Hemodynamics in Healthy Normotensive Subjects versus Treated or Untreated Hypertensive Patients: A Feasibility Study
Open Access
- 26 January 2015
- journal article
- research article
- Published by Wiley in International Journal of Hypertension
- Vol. 2015 (1) , 1-10
Abstract
Objective . Central blood pressure (BP) and vascular indices estimated noninvasively over the 24 hours were compared between normotensive volunteers and hypertensive patients by a pulse wave analysis of ambulatory blood pressure recordings. Methods . Digitalized waveforms obtained during each brachial oscillometric BP measurement were stored in the device memory and analyzed by the validated Vasotens technology. Averages for the 24 hours and for the awake and asleep subperiods were computed. Results . 142 normotensives and 661 hypertensives were evaluated. 24‐hour central BP, pulse wave velocity (PWV), and augmentation index (AI) were significantly higher in the hypertensive group than in the normotensive group (119.3 versus 105.6 mmHg for systolic BP, 75.6 versus 72.3 mmHg for diastolic BP, 10.3 versus 10.0 m/sec for aortic PWV, −9.7 versus −40.7% for peripheral AI, and 24.7 versus 11.0% for aortic AI), whereas reflected wave transit time (RWTT) was significantly lower in hypertensive patients (126.6 versus 139.0 ms). After adjusting for confounding factors a statistically significant between‐group difference was still observed for central BP, RWTT, and peripheral AI. All estimates displayed a typical circadian rhythm. Conclusions . Noninvasive assessment of 24‐hour arterial stiffness and central hemodynamics in daily life dynamic conditions may help in assessing the arterial function impairment in hypertensive patients.Keywords
This publication has 41 references indexed in Scilit:
- 2013 Practice guidelines for the management of arterial hypertension of the European Society of Hypertension (ESH) and the European Society of Cardiology (ESC)Journal Of Hypertension, 2013
- Pulse wave velocity 24-hour monitoring with one-site measurements by oscillometryMedical Devices: Evidence and Research, 2013
- Central aortic blood pressure and augmentation index: comparison between Vasotens® and SphygmoCor® technologyResearch Reports in Clinical Cardiology, 2012
- Ambulatory arterial stiffness index does not accurately assess arterial stiffnessJournal Of Hypertension, 2012
- Central aortic blood pressure, augmentation index, and reflected wave transit time: reproducibility and repeatability of data obtained by oscillometryVascular Health and Risk Management, 2011
- Validation of the BPLab® 24-hour blood pressure monitoring system according to the European standard BS EN 1060-4:2004 and British Hypertension Society protocolMedical Devices: Evidence and Research, 2011
- Arterial wave reflection decreases gradually from supine to uprightBlood Pressure, 2011
- Numerical Validation of a New Method to Assess Aortic Pulse Wave Velocity from a Single Recording of a Brachial Artery Waveform with an Occluding CuffAnnals of Biomedical Engineering, 2010
- Italian Society of Hypertension Guidelines for Conventional and Automated Blood Pressure Measurement in the Office, at Home and Over 24 HoursHigh Blood Pressure & Cardiovascular Prevention, 2008
- Effect of non-invasive calibration of radial waveforms on error in transfer-function-derived central aortic waveform characteristicsClinical Science, 2004