Ultrasound Guided Measurement of Inferior Vena Cava Diameter, Common Carotid Artery Diameter versus Central Venous Pressure for Estimation of Intravascular Volume Status in Septic Shock Patients
Authors:
- Osama Mofreh SalemOSOsama Mofreh Salem
- Mohamad Mohamad AbdElhamed ElghonimyMEMohamad Mohamad AbdElhamed Elghonimy
- Mohamad Samy Mohamad SharafMSMohamad Samy Mohamad Sharaf
Open Access
- 24 April 2026
- journal article
- abstracts
- Published by Damietta Faculty of Medicine, Al-Azhar University, Egypt in The Scientific Journal of Medical Scholar
- Vol. 3 (3) , 38-45
Abstract
Background: In critically ill patients, the fluid resuscitation is crucial and is the first step in treatment protocol. Invasive CVP measurement was used to guide fluid resuscitation. However viralslot, it is time consuming and invasive maneuver. Ultrasound measurement of inferior vena cave and common carotid arteries are suggest to predict the fluid response as well as CVP or even better. The current work designed to compare inferior vena cava diameter and common carotid artery diameter with central venous pressure for estimation of intravascular volume status in septic shock viralslot. Patients and Methods: The study included 60 subjects with septic shock who received vasopressor support viralslot. CVP and ultrasound were performed before and after fluid challenge test. Values of inferior vena cava and common carotid arteries were documented and compared to CVP values. This was performed after full clinical assessment by detailed clinical examination and laboratory workup. Results: The MAP was significantly increased and HR decreased after than before procedure. In addition, CVP, (inferior vena cava), ICVmax, ICV min and common carotid artery diameter (CCAD) were significantly increased, IVC CI (%) was significantly reduced after procedure than basal values. There was significant decrease of IVCmax, IVCmin and CCAD while there was significant increase of IVC CI% with lower ( 8) CVP values. CVP was positively and significantly correlated with IVCmax, IVCmin and CCAD, while it was inversely correlated with IVC CI%. The AUC was over 0.75 for IVCmax, IVCmin and CCAD for prediction of CVP while it was lower than 0.7 for IVC CI%. These data reflected the better predictive power of IVCmax, IVCmin and CCAD. The best cutoff value was 1.35, 1.25, 10.45 and 4.15 for IVCmax, IVCmin, IVC CI% and CCAD successively. Conclusion: IVC and CCA diameters measurement by US may replace CVP measurement for estimation of intravascular volume status in septic shock patients.Keywords
This publication has 32 references indexed in Scilit:
- Not all Shock States Are Created EqualAnesthesiology Clinics, 2023
- Central venous pressure (CVP)Intensive Care Medicine, 2022
- Comparison of inferior vena cava collapsibility and central venous pressure in assessing volume status in shocked patientsAfrican Journal of Emergency Medicine, 2022
- Uncommon Etiologies of ShockCritical Care Clinics, 2022
- Inferior Vena Cava Collapsibility Index: Clinical Validation and Application for Assessment of Relative Intravascular VolumeAdvances in Chronic Kidney Disease, 2021
- Is there an association between central venous pressure measurement and ultrasound assessment of the inferior vena cava?African Journal of Emergency Medicine, 2018
- Comparison of passive leg raising and hyperemia on macrovascular and microvascular responsesMicrovascular Research, 2013
- Inferior Vena Cava Diameter Correlates with Invasive Hemodynamic Measures in Mechanically Ventilated Intensive Care Unit Patients with SepsisThe Journal of Emergency Medicine, 2010
- Emergency Department Bedside Ultrasonographic Measurement of the Caval Index for Noninvasive Determination of Low Central Venous PressureAnnals of Emergency Medicine, 2010
- Intensivist Use of Hand-Carried Ultrasonography to Measure IVC Collapsibility in Estimating Intravascular Volume Status: Correlations with CVPJournal of the American College of Surgeons, 2009