Automatic detection of lytic and blastic thoracolumbar spine metastases on computed tomography
Authors:
Open Access
- 9 February 2013
- journal article
- computer applications
- Published by Springer Nature in European Radiology
- Vol. 23 (7) , 1862-1870
Abstract
Objective To evaluate a computer-aided detection (CADe) system for lytic and blastic spinal metastases on computed tomography (CT). Methods We retrospectively evaluated the CADe system on 20 consecutive patients with 42 lytic and on 30 consecutive patients with 172 blastic metastases. The CADe system was trained using CT images of 114 subjects with 102 lytic and 308 blastic spinal metastases. Lesions were annotated by experienced radiologists. Detected benign lesions were considered false-positive findings. Detector sensitivity and the number of false-positive findings were calculated as the criteria for detector performance, and free-response receiver operating characteristic (FROC) analysis was conducted. Detailed analysis of false-positive and false-negative findings was performed. Results Algorithm runtime is 3 ± 0.5 min per patient. The system achieves a sensitivity of 83 % at 3.5 false positives per patient on average for blastic metastases and a sensitivity of 88 % at 3.7 false positives for lytic metastases. False positives appeared predominantly in the area of degenerative changes in the case of the blastic metastasis detector and in osteoporotic areas in the case of the lytic metastasis detector. Conclusion The CADe system reliably detects thoracolumbar spine metastases in real time. An additional study is planned to evaluate how the bone lesion CADe system improves radiologists’ accuracy and efficiency in a clinical setting. Key Points • Computer-aided detection (CADe) of bone metastases has been developed for spinal CT. • The CADe system exhibits high sensitivity with a tolerable false-positive rate. • Analysis of false-positive detection may further improve the system. • CADe may reduce the number of missed spinal metastases at CT interpretation.Keywords
This publication has 33 references indexed in Scilit:
- Clinically Missed Cancer: How Effectively Can Radiologists Use Computer-Aided Detection?American Journal of Roentgenology, 2012
- Prostate Cancer Detection on Dynamic Contrast-Enhanced MRI: Computer-Aided Diagnosis Versus Single Perfusion Parameter MapsAmerican Journal of Roentgenology, 2011
- CT Colonography: Role of a second reader CAD paradigm in the initial training of radiologistsEuropean Journal of Radiology, 2011
- Computer-aided detection in breast MRI: a systematic review and meta-analysisEuropean Radiology, 2011
- Automated Retrieval of CT Images of Liver Lesions on the Basis of Image Similarity: Method and Preliminary ResultsRadiology, 2010
- Bone metastasis and poor performance status are prognostic factors for survival of carcinoma of unknown primary site in patients treated with systematic chemotherapyAnnals of Oncology, 2009
- Addressing the Coming Radiology Crisis?The Society for Computer Applications in Radiology Transforming the Radiological Interpretation Process (TRIP?) InitiativeJournal of Digital Imaging, 2004
- Bone Imaging in Metastatic Breast CancerJournal of Clinical Oncology, 2004
- Mechanisms of Bone MetastasisNew England Journal of Medicine, 2004
- Do metastases in vertebrae begin in the body or the pedicles? Imaging study in 45 patients.American Journal of Roentgenology, 1992