Current controlled voltage source inverter using Hysteresis controller and PI controller
Authors:
- 1 January 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 45, 1-6
Abstract
Current-controlled pulse width modulated (PWM) voltage source inverters are most widely used in high performance AC drive systems, as they provide high dynamic response. A comparative study between the Hysteresis controller and Proportional-Integral controller using PWM techniques for three-phase voltage source inverter was done. The comparison was done in terms of total harmonic distortion (THD) level at the three phase load current. Simulation was done with the help of Matlab-Simulink environment. The hysteresis controller provides gooddynamic performance, whereas the Proportional-Integral controller provides instantaneous current control and waveshaping, fixed inverter switching frequency resulting in better harmonics.Keywords
This publication has 6 references indexed in Scilit:
- Design of a current mode PI controller for a single-phase PWM inverter2011
- Implementation of Hysteresis Current Control for Single-Phase Grid Connected Inverter2007
- Stationary frame current regulation of PWM inverters with zero steady-state errorIEEE Transactions on Power Electronics, 2003
- Performance parameters of a pulse-width modulation voltage source inverter with proportional-integral controller under non-ideal conditionsElectric Power Systems Research, 1996
- Pulsewidth modulation for electronic power conversionProceedings of the IEEE, 1994
- PWM technique for power MOSFET inverterIEEE Transactions on Power Electronics, 1988