CO2 concentration in day care centres is related to wheezing in attending children
Authors:
- Pedro Carreiro-MartinsPCPedro Carreiro-Martins
- João ViegasJoão Viegas
- Ana Luisa PapoilaAPAna Luisa Papoila
- Daniel AeleneiDaniel Aelenei
- Iolanda CairesICIolanda Caires
- José Araújo-MartinsJAJosé Araújo-Martins
- João Gaspar-MarquesJoão Gaspar-Marques
- Maria Manuela CanoMCMaria Manuela Cano
- Ana Sofia MendesAMAna Sofia Mendes
- Daniel VirellaDVDaniel Virella
- José Rosado-PintoJRJosé Rosado-Pinto
- Paula Leiria-PintoPLPaula Leiria-Pinto
- 4 March 2014
- journal article
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 173 (8) , 1041-1049
Abstract
Poor ventilation at day care centres (DCCs) was already reported, although its effects on attending children are not clear. This study aimed to evaluate the association between wheezing in children and indoor CO2 (a ventilation surrogate marker) in DCC and to identify behaviours and building characteristics potentially related to CO2. In phase I, 45 DCCs from Lisbon and Oporto (Portugal) were selected through a proportional stratified random sampling. In phase II, 3 months later, 19 DCCs were further reassessed after cluster analysis for the greatest difference comparison. In both phases, children’s respiratory health was assessed by ISAAC-derived questionnaires. Indoor CO2 concentrations and building characteristics of the DCC were evaluated in both phases, using complementary methods. Mixed effect models were used to analyze the data. In phase I, which included 3,186 children (mean age 3.1 ± 1.5 years), indoor CO2 concentration in the DCC rooms was associated with reported wheezing in the past 12 months (27.5 %) (adjusted odds ratio (OR) for each increase of 200 ppm 1.04, 95 % CI 1:01 to 1:07). In phase II, the association in the subsample of 1,196 children seen in 19 out of the initial 45 DCCs was not significant (adjusted OR 1.02, 95 % CI 0.96 to 1.08). Indoor CO2 concentration was inversely associated with the practices of opening windows and internal doors and with higher wind velocity. A positive trend was observed between CO2 and prevalence of reported asthma (4.7 %). Conclusion: Improved ventilation is needed to achieve a healthier indoor environment in DCC.Keywords
This publication has 23 references indexed in Scilit:
- Indoor air quality in Montréal area day-care centres, CanadaEnvironmental Research, 2012
- Commemorating 20 years of Indoor AirIndoor Air, 2011
- School air quality related to dry cough, rhinitis and nasal patency in childrenEuropean Respiratory Journal, 2010
- Asthma: epidemiology, etiology and risk factorsCanadian Medical Association Journal, 2009
- The effect of ventilation strategies of child care centers on indoor air quality and respiratory health of children in SingaporeIndoor Air, 2007
- Current asthma and respiratory symptoms among pupils in Shanghai, China: influence of building ventilation, nitrogen dioxide, ozone, and formaldehyde in classroomsIndoor Air, 2006
- Day‐care attendance and increased risk for respiratory and allergic symptoms in preschool ageAllergy, 2006
- Penetration of Nitrogen Oxides and Particles from Outdoor into Indoor Air and Removal of the Pollutants through Filtration of Incoming AirIndoor Air, 2000
- Asthma and Wheezing in the First Six Years of LifeNew England Journal of Medicine, 1995
- Air quality during the winter in Québec day-care centers.American Journal of Public Health, 1992