Stentless versus Stented Bioprosthetic Aortic Valves
Authors:
- 1 March 2009
- journal article
- review article
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 4 (2) , 61-73
Abstract
Objective: This meta-analysis sought to determine whether stentless bioprosthetic valves improve clinical and resource outcomes compared with stented valves in patients undergoing aortic valve replacement. Methods: A comprehensive search was undertaken to identify all randomized and nonrandomized controlled trials comparing stentless to stented bioprosthetic valves in patients undergoing aortic valve replacement available up to March 2008. The primary outcomes were clinical and resource outcomes in randomized controlled trial (RCT). Secondary outcomes clinical and resource outcomes in nonrandomized controlled trial (non-RCT). Odds ratios (OR), weighted mean differences (WMD), or standardized mean differences and their 95% confidence intervals (CI) were analyzed as appropriate. Results: Seventeen RCTs published in 23 articles involving 1317 patients, and 14 non-RCTs published in 18 articles involving 2485 patients were included in the meta-analysis. For the primary analysis of randomized trials, mortality for stentless versus stented valve groups did not differ at 30 days (OR 1.36, 95% CI 0.68–2.72), 1 year (OR 1.01, 95% CI 0.55–1.85), or 2 to 10 years follow-up (OR 0.82, 95% CI 0.50–1.33). Aggregate event rates for all-cause mortality at 30 days were 3.7% versus 2.9%, at 1 year were 5.5% versus 5.9% and at 2 to 10 years were 17% versus 19% for stentless versus stented valve groups, respectively. Stroke or neurologic complications did not differ between stentless (3.6%) and stented (4.0%) valve groups. Risk of prosthesis-patient mismatch was numerically lower in the stentless group (11.0% vs. 31.3%, OR 0.30, 95% CI 0.05–1.66), but this parameter was reported in few trials and did not reach statistical significance. Effective orifice area index was significantly greater for stentless aortic valve compared with stented valves at 30 days (WMD 0.12 cm2/m2), at 2 to 6 months (WMD 0.15 cm2/m2), and at 1 year (WMD 0.26 cm2/m2). Mean gradient at 1 month was significantly lower in the stentless valve group (WMD −6 mm Hg), at 2 to 6 month follow-up (WMD −4 mm Hg,), at 1 year follow-up (WMD −3 mm Hg) and up to 3 year follow-up (WMD −3 mm Hg) compared with the stented valve group. Although the left ventricular mass index was generally lower in the stentless group versus the stented valve group, the aggregate estimates of mean difference did not reach significance during any time period of follow-up (1 month, 2–6 months, 1 year, and 8 years). Conclusions: Evidence from randomized trials shows that subcoronary stentless aortic valves improve hemodynamic parameters of effective orifice area index, mean gradient, and peak gradient over the short and long term. These improvements have not led to proven impact on patient morbidity, mortality, and resource-related outcomes; however, few trials reported on clinical outcomes beyond 1 year and definitive conclusions are not possible until sufficient evidence addresses longer-term effects.Keywords
This publication has 37 references indexed in Scilit:
- Is a stentless aortic valve superior to conventional bioprosthetic valves for aortic valve replacement?Interactive CardioVascular and Thoracic Surgery, 2007
- Stented versus Stentless Bioprostheses in Aortic Valve Stenosis: Effect on Left Ventricular RemodellingThe Heart Surgery Forum, 2007
- Stentless and stented aortic valve replacement in elderly patients: factors affecting midterm clinical and hemodynamical outcomeEuropean Journal of Cardio-Thoracic Surgery, 2006
- Short-term hemodynamic advantages of stentless CryoLife-O'Brien valve over stented bioprostheses for aortic valve replacementInteractive CardioVascular and Thoracic Surgery, 2006
- Impact of Stentless Aortic Valves on Left Ventricular Function and Hypertrophy: Current Best Available EvidenceJournal of Cardiac Surgery, 2006
- Stentless Aortic Valves are Hemodynamically Superior to Stented Valves During Mid-Term Follow-Up: A Large Retrospective StudyThe Annals of Thoracic Surgery, 2005
- Early Regional Assessment of LV Mass Regression and Function after Stentless Valve Replacement: Comparative Randomized StudyThe Heart Surgery Forum, 2004
- Does the type of prosthesis influence early left ventricular mass regression after aortic valve replacement? Assessment with magneticresonance imagingAmerican Heart Journal, 2003
- Stentless or stented aortic valve implants in elderly patients?1European Journal of Cardio-Thoracic Surgery, 1999
- Prognostic Implications of Echocardiographically Determined Left Ventricular Mass in the Framingham Heart StudyNew England Journal of Medicine, 1990