Optimal Joint Detection and Estimation That Maximizes ROC-Type Curves
Open Access
- 13 April 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 35 (9) , 2164-2173
Abstract
Combined detection-estimation tasks are frequently encountered in medical imaging. Optimal methods for joint detection and estimation are of interest because they provide upper bounds on observer performance, and can potentially be utilized for imaging system optimization, evaluation of observer efficiency, and development of image formation algorithms. We present a unified Bayesian framework for decision rules that maximize receiver operating characteristic (ROC)-type summary curves, including ROC, localization ROC (LROC), estimation ROC (EROC), free-response ROC (FROC), alternative free-response ROC (AFROC), and exponentially-transformed FROC (EFROC) curves, succinctly summarizing previous results. The approach relies on an interpretation of ROC-type summary curves as plots of an expected utility versus an expected disutility (or penalty) for signal-present decisions. We propose a general utility structure that is flexible enough to encompass many ROC variants and yet sufficiently constrained to allow derivation of a linear expected utility equation that is similar to that for simple binary detection. We illustrate our theory with an example comparing decision strategies for joint detection-estimation of a known signal with unknown amplitude. In addition, building on insights from our utility framework, we propose new ROC-type summary curves and associated optimal decision rules for joint detection-estimation tasks with an unknown, potentially-multiple, number of signals in each observation.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering
This publication has 35 references indexed in Scilit:
- Osteoporosis Imaging: State of the Art and Advanced ImagingRadiology, 2012
- Impact of Tumor Size and Tracer Uptake Heterogeneity in 18F-FDG PET and CT Non–Small Cell Lung Cancer Tumor DelineationJournal of Nuclear Medicine, 2011
- An Equivalent Relative Utility Metric for Evaluating Screening MammographyMedical Decision Making, 2009
- Collimator optimization in SPECT based on a joint detection and localization taskPhysics in Medicine & Biology, 2009
- Imaging Surrogates of Tumor Response to Therapy: Anatomic and Functional BiomarkersJournal of Nuclear Medicine, 2009
- Aperture optimization in emission imaging using ideal observers for joint detection and localizationPhysics in Medicine & Biology, 2008
- Visualization and Detection-Localization on Computed Tomographic ImagesInvestigative Radiology, 1991
- Satisfaction of Search in Diagnostic RadiologyInvestigative Radiology, 1990
- A new digital electronic caliper for measurement of coronary arterial stenosis: Comparison with visual estimates and computer-assisted measurementsThe American Journal of Cardiology, 1984
- Basic principles of ROC analysisSeminars in Nuclear Medicine, 1978