Evaluation of wetting condition and its effects on pollution flashover voltage of aerodynamic insulators
Authors:
- 14 November 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 23 (5) , 2875-2882
Abstract
The flashover performance of insulators is significantly affected by the degrees and ways of wetting the pollution layer. However, there have only been a few reports on the wetting condition and its effects on the flashover characteristics of pollution on insulators to date. In this paper, a phase-angle difference-based method is proposed to test the wetting conditions of the pollution layer on insulators. A corresponding measuring device is also developed. The wetting process of the pollution layer on aerodynamic-type glass insulators is studied in an artificial climate chamber using the developed device. The related flashover performance is studied via the even-rising voltage method. Test results show that the phase-angle difference (PAD) curve accurately reflects the entire wetting process of the pollution layer from the initial stage, through the saturated stage to the oversaturated and washing away stages. Over the wetting process, the PAD curve initially drops sharply, and then remains stable for a few minutes before eventually rising slowly to the initial value. The PAD curve has its lowest value when the pollution layer is wetted to saturation, which occurs after approximately 5 min in our experiments. The flashover voltage characteristics of insulators are also significantly affected by the wetting conditions of the pollution layer. The flashover voltage in the saturated stage is shown to be lower than that in the other stages. Therefore, to improve the accuracy of the artificial pollution tests, quantitative methods (including PAD) should be used to obtain the exact time of wetting to saturation.Keywords
This publication has 13 references indexed in Scilit:
- Online Optimal Generation Control Based on Constrained Distributed Gradient AlgorithmIEEE Transactions on Power Systems, 2014
- Study on AC Flashover Performance for Different Types of Porcelain and Glass Insulators With Non-Uniform PollutionIEEE Transactions on Power Delivery, 2013
- Effects of artificial polluting methods on AC flashover voltage of composite insulatorsIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Study of the influence of test methods on DC pollution flashover voltage of insulator strings and its flashover processIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- Pollution tests for polymeric insulators made of hydrophobicity transfer materialsIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- Effect of Wetting Conditions on The Contamination Flashover Voltages of Polymer Insulators2006
- Variable-voltage application for insulator pollution testsIEEE Transactions on Power Delivery, 1988
- Effect of Contamination on the Leakage Current of Inland Desert InsulatorsIEEE Transactions on Electrical Insulation, 1984
- AC Flashover Characteristics of Long AIR Gaps And Insulator Strings Under Fog ConditionsIEEE Transactions on Power Apparatus and Systems, 1981
- Artificial- and natural-pollution tests on outdoor 400 kV substation insulatorsProceedings of the Institution of Electrical Engineers, 1971