Clinical and procedural outcomes of percutaneous coronary intervention for de novo lesions involving the ostial left circumflex coronary artery
Open Access
- 7 November 2023
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 102 (6) , 1048-1056
Abstract
Background: Percutaneous treatment for ostial left circumflex artery (LCx) lesions is known to be associated with suboptimal results.Aims: The present study aims to assess the procedural and long‐term clinical outcomes of percutaneous coronary intervention (PCI) for de novo ostial LCx lesions overall and according to the coronary revascularization strategy.Methods: Consecutive patients undergoing PCI with second generation drug eluting stents or drug coated balloons for de novo ostial LCx lesions in three high‐volume Italian centers between 2012 and 2021 were retrospectively evaluated. The primary endpoint was target‐vessel revascularization (TVR) at 2 years. Secondary endpoints included major adverse cardiovascular and cerebrovascular events (MACCE), target lesion revascularization, myocardial infarction, stroke, all‐cause death, and repeat revascularization.Results: A total of 366 patients were included in the analysis with a median follow‐up of 901 (IQR: 450−1728) days. 79.5% of the patients were male, 33.6% were diabetic, 49.7% had a previous PCI, and 23.1% a prior surgical revascularization. Very ostial LCx stenting was performed in 34.1%, crossover from left main to LCx in 17.3%, and a two‐stent strategy in 48.6% of cases, respectively. In the overall population, the incidence of TVR at 2 years was 19.0% while MACCE rate was 25.7%. No major differences in clinical outcomes were found according to the stenting strategy. Use of intracoronary imaging was associated with fewer MACCE (HR: 0.47, 95% CI: 0.25−1.13, p = 0.01), while the diameter of the stent implanted in the ostial LCx was associated with less TVR (HR: 0.43, 95% CI: 0.25−0.75, p = 0.002).Conclusions: Percutaneous revascularization of the ostial LCx is associated with a high rate of TVR, regardless of the stenting strategy. Intracoronary imaging and proper stent sizing may reduce the failure rates.Keywords
This publication has 17 references indexed in Scilit:
- 3-Year Outcomes of the DKCRUSH-V Trial Comparing DK Crush With Provisional Stenting for Left Main Bifurcation LesionsJACC: Cardiovascular Interventions, 2019
- Double Kissing Crush Versus Provisional Stenting for Left Main Distal Bifurcation LesionsJACC, 2017
- Clinical Impact of Intravascular Ultrasound Guidance in Drug-Eluting Stent Implantation for Unprotected Left Main Coronary DiseaseJACC: Cardiovascular Interventions, 2014
- Single‐stent crossover technique from distal unprotected left main coronary artery to the left circumflex arteryCatheterization and Cardiovascular Interventions, 2013
- Comparison of Double Kissing Crush Versus Culotte Stenting for Unprotected Distal Left Main Bifurcation LesionsJACC, 2013
- 3-Dimensional Bifurcation Angle Analysis in Patients With Left Main DiseaseJACC: Cardiovascular Interventions, 2010
- Impact of Intravascular Ultrasound Guidance on Long-Term Mortality in Stenting for Unprotected Left Main Coronary Artery StenosisCirculation: Cardiovascular Interventions, 2009
- The bifurcation study using 64 multislice computed tomographyCatheterization and Cardiovascular Interventions, 2008
- Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantationEuropean Heart Journal, 2006
- Contribution of Stent Underexpansion to Recurrence After Sirolimus-Eluting Stent Implantation for In-Stent RestenosisCirculation, 2004