Photoplethysmographic Time-Domain Heart Rate Measurement Algorithm for Resource-Constrained Wearable Devices and its Implementation
Open Access
Abstract
This paper presents an algorithm for the measurement of the human heart rate, using photoplethysmography (PPG), i.e., the detection of the light at the skin surface. The signal from the PPG sensor is processed in time-domain; the peaks in the preprocessed and conditioned PPG waveform are detected by using a peak detection algorithm to find the heart rate in real time. Apart from the PPG sensor, the accelerometer is also used to detect body movement and to indicate the moments in time, for which the PPG waveform can be unreliable. This paper describes in detail the signal conditioning path and the modified algorithm, and it also gives an example of implementation in a resource-constrained wrist-wearable device. The algorithm was evaluated by using the publicly available PPG-DaLia dataset containing samples collected during real-life activities with a PPG sensor and accelerometer and with an ECG signal as ground truth. The quality of the results is comparable to the other algorithms from the literature, while the required hardware resources are lower, which can be significant for wearable applications.Keywords
Funding Information
- E-Pionier - using the potential of universities to improve the innovation of ICT solutions in the public sector (17/02/2018/UD)
This publication has 22 references indexed in Scilit:
- Heart Rate Estimation From Wrist-Worn Photoplethysmography: A ReviewIEEE Sensors Journal, 2019
- A survey of energy-efficient context recognition systems using wearable sensors for healthcare applicationsPervasive and Mobile Computing, 2017
- A Mobile Device System for Early Warning of ECG AnomaliesSensors, 2014
- Epileptic Spike Detection Using a Kalman Filter Based Approach2006
- Improved peak detection in mass spectrum by incorporating continuous wavelet transform-based pattern matchingBioinformatics, 2006
- An Automatic Beat Detection Algorithm for Pressure SignalsIEEE Transactions on Biomedical Engineering, 2005
- Auto-threshold peak detection in physiological signals2005
- The use of the Hilbert transform in ECG signal analysisComputers in Biology and Medicine, 2001
- An approach to cardiac arrhythmia analysis using hidden Markov modelsIEEE Transactions on Biomedical Engineering, 1990
- A Real-Time QRS Detection AlgorithmIEEE Transactions on Biomedical Engineering, 1985