MR-guided breast biopsy at 3T: diagnostic yield of large core needle biopsy compared with vacuum-assisted biopsy
Open Access
- 14 September 2011
- journal article
- breast
- Published by Springer Nature in European Radiology
- Vol. 22 (2) , 341-349
Abstract
Objective The purpose of this study was to evaluate two MR-guided biopsy techniques at 3 T, large core needle breast biopsy (LCNB) and vacuum-assisted breast biopsy (VAB) and to compare the diagnostic yield and rate of complications to determine the optimal biopsy technique at 3 T. Methods 55 LCNB and 64 VAB were consecutively performed. Benign biopsy results were verified by retrospective correlation of histology, with pre-interventional, post-interventional MRI studies and follow-up and were classified as representative or non-representative. Time to follow-up was up to 2 years for the considered non-representative benign lesions. Statistical analysis was performed using the Chi-squared test. Results LCNB was technically successful in 100% of patients (55/55) and VAB in 98% of patients (63/64). Histopathological analysis resulted in 45 (82%) benign, 3 (5%) high-risk and 7 (13%) malignant lesions for LCNB and 43 (67%) benign, 3 (5%) high-risk and 18 (28%) malignant lesions. Distribution was significantly different (p < 0.001), favouring VAB over LCNB. Conclusion Because of the substantially higher diagnostic yield and certainty of a benign diagnosis, VAB is the optimal biopsy technique at 3 T. LCNB should be considered when VAB is not feasible.Keywords
This publication has 39 references indexed in Scilit:
- Meta-Analysis of MR Imaging in the Diagnosis of Breast LesionsRadiology, 2008
- Cancer yield of probably benign breast MR examinationsJournal of Magnetic Resonance Imaging, 2007
- MRI-Guided Percutaneous Biopsy of Breast Lesions: Materials, Techniques, Success Rates, and Management in Patients with Suspected Radiologic-Pathologic MismatchMagnetic Resonance Imaging Clinics of North America, 2006
- Contrast-enhanced MR Imaging of the Breast at 3.0 and 1.5 T in the Same Patients: Initial ExperienceRadiology, 2006
- MR Imaging–guided 9-gauge Vacuum-assisted Core-Needle Breast Biopsy: Initial ExperienceRadiology, 2006
- Relaxation times of breast tissue at 1.5T and 3T measured using IDEALJournal of Magnetic Resonance Imaging, 2005
- MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy: Initial Clinical ExperienceAmerican Journal of Roentgenology, 2005
- Frequency of malignancy in lesions classified as probably benign after dynamic contrast‐enhanced breast MRI examinationJournal of Magnetic Resonance Imaging, 2005
- Enhancement Effects and Relaxivities of Gadolinium-DTPA at 1.5 versus 3 Tesla: A Phantom StudyMagnetic Resonance in Medical Sciences, 2005
- Follow-up of Palpable Circumscribed Noncalcified Solid Breast Masses at Mammography and US: Can Biopsy Be Averted?Radiology, 2004