Intraocular concentration of moxifloxacin after intracameral injection combined with presoaked intraocular lenses
Authors:
- 1 April 2014
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 40 (4) , 639-643
Abstract
Purpose To evaluate the impact of intraocular lens (IOL) moxifloxacin presoaking time on the intraocular concentration of moxifloxacin achieved after intracameral moxifloxacin injection. Setting Harlan Biotech Israel, Rehovot, Israel. Design Laboratory study Methods Sixty eyes of 30 rabbits were divided into 2 groups after crystalline lens evacuation. In Group A (30 eyes), hydrophilic acrylic IOLs presoaked for 15 minutes in 5 mg/mL moxifloxacin were implanted. In Group B (30 eyes), the same hydrophilic acrylic IOLs presoaked in the same solution for 24 hours were implanted. Intracameral injection of 100 mcg/0.1 moxifloxacin was performed at the end of surgery in both groups. Aqueous humor samples were obtained 2, 4, 6, 8, and 10 hours after IOL implantation and were analyzed by high-performance liquid chromatography to determine the antibiotic concentration. Results Group A achieved mean postoperative moxifloxacin concentrations of 18.60 mcg/mL ± 8.80 (SD), 4.08 ± 6.03 mcg/mL, 1.50 ± 0.75 mcg/mL, 0.21 ± 0.09 mcg/mL, and 0.12 ± 0.04 mcg/mL at 2, 4, 6, 8, and 10 hours, respectively. Group B achieved mean moxifloxacin concentrations of 17.25 ± 6.27 mcg/mL, 9.46 ± 2.22 mcg/mL, 6.26 ± 1.22 mcg/mL, 4.34 ± 0.42 mcg/mL, and 3.62 ± 1.02 mcg/mL, respectively. Moxifloxacin concentrations at 6, 8, and 10 hours were statistically significantly higher in Group B than in Group A (all P < .0001). Conclusions Combining intracameral moxifloxacin injection with implantation of moxifloxacin-presoaked hydrophilic acrylic IOLs yielded high intraocular concentrations of moxifloxacin. Higher concentrations were found with longer presoaking. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 18 references indexed in Scilit:
- Hydrophilic Acrylic Intraocular Lens as a Drug Delivery System: Influence of the Presoaking Time and Comparison to Intracameral InjectionJournal of Ocular Pharmacology and Therapeutics, 2013
- Acute-onset nosocomial endophthalmitis after cataract surgeryJournal of Cataract & Refractive Surgery, 2009
- Prevention of endophthalmitis by collagen shields presoaked in fourth-generation fluoroquinolones versus by topical prophylaxisJournal of Cataract & Refractive Surgery, 2008
- Perspectives on antibiotics for postoperative endophthalmitis prophylaxis: Potential role of moxifloxacinJournal of Cataract & Refractive Surgery, 2007
- Prophylaxis of postoperative endophthalmitis following cataract surgery: Results of the ESCRS multicenter study and identification of risk factorsJournal of Cataract & Refractive Surgery, 2007
- Safety of prophylactic intracameral moxifloxacin 0.5% ophthalmic solution in cataract surgery patientsJournal of Cataract & Refractive Surgery, 2007
- Collagen Shields as a Drug Delivery System for the Fourth-Generation FluoroquinolonesOphthalmologica, 2006
- Hydrophilic acrylic intraocular lens as a drug-delivery system for fourth-generation fluoroquinolonesJournal of Cataract & Refractive Surgery, 2006
- Intracameral Vigamox® (Moxifloxacin 0.5%) is Non-Toxic and Effective in Preventing Endophthalmitis in a Rabbit ModelAmerican Journal of Ophthalmology, 2005
- Acute-onset Endophthalmitis After Cataract Surgery (2000–2004): Incidence, Clinical Settings, and Visual Acuity Outcomes After TreatmentAmerican Journal of Ophthalmology, 2005