Pressure transducer mounts for internal blast measurements on thin metal walls

Authors:

Abstract
Three mounts are described for installing pressure transducers on thin walls for internal blast measurements in which the walls undergo ductile rupture. Details of the mounts are presented and each mount is evaluated from several examples of pressure-time profiles obtained from thin steel walled cubes and ship compartment studies. Two designs proved effective, one having a flange and a sheath to protect the transducer, and another, a simpler and lighter design, consisting of a welded ring.
Keywords

This publication has 1 reference indexed in Scilit: