Circulating Tissue Thromboplastin during Hip Surgery

Authors:
  • KGK.-E. Giercksky
    K.-E. Giercksky
  • EBE. BjØRklid
    E. BjØRklid
  • HPH. Prydz
    H. Prydz
  • HRH. Renck
    H. Renck

Abstract
An immunoradiometric assay for tissue thromboplastin has been established. Blood levels in 6 patients undergoing total hip replacement have been determined. In 3 patients, high levels of circulating apoprotein III were found at various stages of the operation, showing a release of tissue thromboplastin chiefly during impaction of the prosthesis into the femoral bone. The other 3 patients had low or undetectable levels.