Evaluation of Suture Abrasion Against Rotator Cuff Tendon and Proximal Humerus Bone
- 29 November 2007
- journal article
- research article
- Published by Wiley in Arthroscopy
- Vol. 24 (3) , 329-334
Abstract
Purpose: This study evaluates the abrasion properties of different suture materials through the rotator cuff tendon and proximal humerus tuberosity bone. Methods: Three types of sutures were compared: monofilament polypropylene, braided polyester, and braided polyblend polyester with a polyethylene core. For soft‐tissue testing, the suture was passed through the infraspinatus tendons of 11 cadaveric shoulders. The suture was cycled with a fixed load, and the migration of the suture as it cut through the tissue was measured at intervals of 5 cycles, for a total of 50 cycles. For tuberosity testing, the sutures were passed through a transosseous tunnel created in the lesser tuberosity, and the suture was cycled with a fixed load until suture failure occurred. Results: On soft‐tissue testing, the monofilament suture showed the least amount of abrasion, followed by the braided polyblend and then the braided polyester suture (cutting rate of 0.06 ± 0.11 mm/cycle, 0.99 ± 0.44 mm/cycle, and 1.75 ± 0.91 mm/cycle, respectively; P < .0001). On tuberosity testing, suture breakage for the braided polyblend suture occurred at 501.3 ± 220.4 cycles. The braided polyester and monofilament sutures broke after 256.6 ± 120.9 and 193.5 ± 144.8 cycles, respectively. The difference between cycles to failure of the polyblend and latter 2 sutures was statistically significant ( P < .0001). Conclusions: This study shows increased abrasion properties for braided sutures compared with monofilament sutures, as well as different abrasion properties among different types of braided sutures. Furthermore, the braided polyblend suture showed significantly increased cycles before suture failure through a transosseous tunnel. Clinical Relevance: Although development of new suture materials has increased their failure strength, further advancements in suture material design should focus on decreasing soft‐tissue abrasion properties and increasing strength to suture failure when cycled through bone.Keywords
This publication has 18 references indexed in Scilit:
- Sutures and Suture Anchors—Update 2006Arthroscopy, 2006
- Cyclic Loading of Rotator Cuff Repairs: An In Vitro Biomechanical Comparison of Bioabsorbable Tacks With Transosseous SuturesArthroscopy, 2005
- In vitro analysis of rotator cuff repairs: A comparison of arthroscopically inserted tacks or anchors with open transosseous repairsArthroscopy, 2005
- Sutures and suture anchors: update 2003Arthroscopy, 2003
- PULLOUT STRENGTH OF SUTURE ANCHORS USED IN ROTATOR CUFF REPAIRJournal of Bone and Joint Surgery, 2003
- Cyclic loading of anchor‐based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixationArthroscopy, 1997
- Strength of Fixation with Transosseous Sutures in Rotator Cuff Repair*Journal of Bone and Joint Surgery, 1997
- The relationship of suture anchor failure and bone density to proximal humerus location: A cadaveric studyArthroscopy, 1997
- Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failureArthroscopy, 1997
- Fixation strength of rotator cuff repair swith suture anchors and the transosseous suture techniqueJournal of Shoulder and Elbow Surgery, 1996