Highly Cross-linked, Electron-Beam-Irradiated, Melted Polyethylene
- 1 December 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 429 (429) , 63-67
Abstract
Extensive new evidence generated within the past the year provides strong support for the use of electron-beam highly cross-linked, subsequently melted ultra-high molecular weight polyethylene in total hip replacement arthroplasty. In terms of wear reduction, three studies involving three different demographic groups and two different measurement techniques have found that the femoral head penetration with this type of polyethylene after bedding in has finished taking place is less than 10 micra per year. This wear rate is similar to the wear rate of metal-on-metal and ceramic-on-ceramic articulations. Retrieval specimens up to 3 years after insertion confirmed the minimal wear by exhibiting persisting machine marks throughout the inside diameter of the liner. Extensive studies show no evidence of oxidation, confirming the absence of residual free radicals. No evidence of fatigue failure exists except three known cases out of 150,000, in which malposition of the acetabular component produced abnormally high contact stresses on unsupported polyethylene. The in vivo wear, oxidation resistance, and mechanical properties of this alternative bearing material are excellent, with in vivo durations now exceeding five years. The other major advantages over hard-on-hard bearings including familiarity, adaptability, forgiveness, and cost seem to be compelling.Keywords
This publication has 26 references indexed in Scilit:
- THE OTTO AUFRANC AWARD: Highly Cross-linked Polyethylene in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2004
- Surface analysis of early retrieved acetabular polyethylene linersThe Journal of Arthroplasty, 2004
- Fractures of Ceramic BearingsClinical Orthopaedics and Related Research, 2003
- Long‐term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparationJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2003
- Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement modelJournal of Orthopaedic Research, 2002
- A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical propertiesThe Journal of Arthroplasty, 2001
- Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patternsThe Journal of Arthroplasty, 2000
- Development of an extremely wear‐resistant ultra high molecular weight polythylene for total hip replacementsJournal of Orthopaedic Research, 1999
- Cobalt and Chromium Concentrations in Patients With Metal on Metal Total Hip ReplacementsClinical Orthopaedics and Related Research, 1996
- The appearances of wear on polyethylene—a comparison of in vivo and in vitro wear surfacesJournal of Biomedical Materials Research, 1978