Interobserver Agreement and Accuracy in Interpreting mpMRI of the Prostate: a Systematic Review
- 1 January 2022
- journal article
- review article
- Published by Springer Nature in Current Urology Reports
- Vol. 23 (1) , 1-10
Abstract
Purpose of Review To present the latest evidence related to interobserver agreement and accuracy; evaluate the strengths, weaknesses, and implications of use; and outline opportunities for improvement and future development of the Prostate Imaging Reporting and Data System version 2.1 (PI-RADS v2.1) for detection of prostate cancer (PCa) on multiparametric magnetic resonance imaging (mpMRI). Recent Findings Our review of currently available evidence suggests that recent improvements to the PI-RADS system with PI-RADS v2.1 slightly improved interobserver agreement, with generally high sensitivity and moderate specificity for the detection of clinically significant PCa. Recent evidence additionally demonstrates substantial improvement in diagnostic specificity with PI-RADS v2.1 compared with PI-RADS v2. However, results of studies examining the comparative performance of v2.1 are limited by small sample sizes and retrospective cohorts, potentially introducing selection bias. Some studies suggest a substantial improvement between v2.1 and v2, while others report no statistically significant difference. Additionally, in PI-RADS v2.1, the interpretation and reporting of certain findings remain subjective, particularly for category 2 lesions, and reader experience continues to vary significantly. These factors further contribute to a remaining degree of interobserver variability and findings of improved performance among more experienced readers. Summary PI-RADS v2.1 appears to show at least minimal improvement in interobserver agreement, diagnostic performance, and both sensitivity and specificity, with greater improvements seen among more experienced readers. However, given the decrescent nature of these improvements and the limited power of all studies examined, the clinical impact of this progress may be marginal. Despite improvements in PI-RADS v2.1, practitioner experience in interpreting mpMRI of the prostate remains the most important factor in prostate cancer detection.Keywords
This publication has 27 references indexed in Scilit:
- PI-RADS version 2.1: one small step for prostate MRIClinical Radiology, 2019
- Prostate Imaging Reporting and Data System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2European Urology, 2019
- Epidemiology of Prostate CancerWorld Journal of Oncology, 2019
- Development and internal validation of PI-RADs v2-based model for clinically significant prostate cancerWorld Journal of Surgical Oncology, 2018
- Standards for MRI reporting—the evolution to PI-RADS v 2.0Translational Andrology and Urology, 2017
- Proposed Adjustments to PI-RADS Version 2 Decision Rules: Impact on Prostate Cancer DetectionRadiology, 2017
- Standardized Reporting of Prostate MRI: Comparison of the Prostate Imaging Reporting and Data System (PI-RADS) Version 1 and Version 2PLOS ONE, 2016
- PI-RADS Version 2: A Pictorial UpdateRadioGraphics, 2016
- Prostate imaging reporting and data system version 2 (PI-RADS v2): a pictorial reviewAbdominal Radiology, 2016
- Prostate MRI based on PI-RADS version 2: how we review and reportCancer Imaging, 2016