Comparison of the Performance of Two Different Spectral-Domain Optical Coherence Tomography Angiography Devices in Clinical Practice
Authors:
- Luigi Antonio De VitisLVLuigi Antonio De Vitis
- Lucia BenattiLBLucia Benatti
- Livia TomassoLTLivia Tomasso
- Giovanni BaldinGBGiovanni Baldin
- Adriano CarnevaliACAdriano Carnevali
- Lea QuerquesLQLea Querques
- Giuseppe QuerquesGQGiuseppe Querques
- Francesco BandelloFBFrancesco Bandello
- 12 July 2016
- journal article
- research article
- Published by S. Karger AG in Ophthalmic Research
- Vol. 56 (3) , 155-162
Abstract
Purpose: To compare the performance of two different spectral-domain optical coherence tomography angiography (OCTA) devices in clinical practice by evaluating examination execution time and the number of motion artifacts per image. Methods: Seventy-six patients affected by different ocular diseases and 13 healthy subjects consecutively underwent assessments by two different OCTA devices: AngioPlex (Zeiss Meditec, Inc., Dublin, Calif., USA) and AngioVue (OptoVue, Inc., Fremont, Calif., USA). Two different operators (L.A.D.V. and L.B.) measured execution times, excluded low-quality images, and counted the number of motion artifacts per image. Results: The mean execution time was shorter with AngioPlex than with AngioVue for all subjects (3 min 32 s ± 1 min 45 s vs. 4 min 35 s ± 1 min 11 s; p < 0.0001), for the healthy subjects (2 min 31 s ± 45 s vs. 4 min 1 s ± 53 s; p = 0.003), and for the patients (3 min 44 s ± 1 min 48 s vs. 4 min 42 s ± 1 min 13 s; p < 0.0001). The percentages of available images, low-signal-strength images, and images impossible to analyze of the total acquired images obtained using AngioPlex or AngioVue were 85, 6, and 9% and 56, 29, and 15%, respectively. The mean number of motion artifacts was significantly lower in images obtained using AngioPlex than in images obtained using AngioVue for all patients (6.5 ± 5.9 vs. 12.6 ± 8.5; p < 0.0001), for the healthy subjects (6.5 ± 4.6 vs. 10.9 ± 7.9; p = 0.0009), and for the patients (6.6 ± 6.3 vs. 13.1 ± 8.7; p < 0.0001). There was no correlation between the number of artifacts and execution time or patients' age. Conclusion: AngioPlex and AngioVue are useful devices in clinical practice. AngioPlex requires a shorter execution time and provides a higher number of images available for analysis with fewer motion artifacts.Keywords
This publication has 26 references indexed in Scilit:
- Optical Coherence Tomography Angiography of Idiopathic Polypoidal Choroidal Vasculopathy2016
- Optical Coherence Tomography Angiography of Diabetic Retinopathy2016
- IMAGE ARTIFACTS IN OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHYRetina, 2015
- Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiographyBiomedical Optics Express, 2015
- Retinal Vascular Layers Imaged by Fluorescein Angiography and Optical Coherence Tomography AngiographyJAMA Ophthalmology, 2015
- Review of speckle and phase variance optical coherence tomography to visualize microvascular networksJournal of Biomedical Optics, 2013
- Split-spectrum amplitude-decorrelation angiography with optical coherence tomographyOptics Express, 2012
- In vivo volumetric imaging of human retinal circulation with phase-variance optical coherence tomographyBiomedical Optics Express, 2011
- Using ultrahigh sensitive optical microangiography to achieve comprehensive depth resolved microvasculature mapping for human retinaJournal of Biomedical Optics, 2011
- Phase-Contrast OCT Imaging of Transverse Flows in the Mouse Retina and ChoroidInvestigative Ophthalmology & Visual Science, 2008