Deficiencies in Root Canal Fillings Subsequent to Adaptive Instrumentation of Oval Canals
Open Access
Abstract
The purpose of this study was to explore the influence of instrumentation and the potential for debris deposition using XP-endo shaper plus (XP-SP) and full-sequence SAF (F-SAF) on the adaption of thermoplastic root canal fillings in oval canals. Following the manufacturer’s instructions, ninety human permanent mandibular incisors with a single oval canal 6 mm from the apex (verified using pre-operative CBCT scanning) were instrumented with XP-SP and F-SAF. Obtura III Max apparatus was used for root canal obturation without the use of a root canal sealer. The roots were then sectioned 6 mm from the apex and examined with a digital stereomicroscope at x25 magnification to assess the root canal fillings. The F-SAF was associated with a significantly higher (p < 0.01) percentage of entire adaptation of the root fillings (76%) compared to the XP-SP (57%). Furthermore, the XP-SP group was also associated with higher (p < 0.01) defective obturation with debris at 17% and with voids at 26%. However, the F-SAF had lower percentages of defective obturations (7% with debris and 17% with voids). The quality of obturation of oval canals instrumented using full-sequence SAF was better.Keywords
This publication has 28 references indexed in Scilit:
- Percentage of Gutta-percha Filled Areas in Canals Obturated with Cross-linked Gutta-percha Core-carrier Systems, Single-Cone and Lateral Compaction TechniqueJournal of Endodontics, 2016
- Contemporary obturation of the root canal systemBritish Dental Journal, 2014
- The self-adjusting file (SAF) system: An evidence-based updateJournal of Conservative Dentistry, 2014
- Self-Adjusting File Cleaning-Shaping-Irrigation System Optimizes the Filling of Oval-shaped Canals with Thermoplasticized Gutta-perchaJournal of Endodontics, 2012
- Micro–computed Tomography Evaluation of the Preparation of Long Oval Root Canals in Mandibular Molars with the Self-adjusting FileJournal of Endodontics, 2011
- The Quality of Root Canal Preparation and Root Canal Obturation in Canals Treated with Rotary versus Self-adjusting Files: A Three-dimensional Micro-computed Tomographic StudyJournal of Endodontics, 2010
- Limited Ability of Three Commonly Used Thermoplasticized Gutta-Percha Techniques in Filling Oval-shaped CanalsJournal of Endodontics, 2008
- Filling Root Canals in Three DimensionsJournal of Endodontics, 2006
- Methods of filling root canals: principles and practicesEndodontic Topics, 2005
- A comparison of canal preparations in straight and curved root canalsOral Surgery, Oral Medicine, Oral Pathology, 1971